CAUTION: Installation and maintenance must be done by an NFI Certified or other qualified professional
installer. Read these instructions before installing this outdoor fire table. Be sure you understand all safety
precautions and warnings contained in this manual.
1. FOR OUTDOOR USE ONLY. THIS UNIT MUST BE INSTALLED AT LEAST 36" FROM ANY
COMBUSTIBLE WALLS OR MATERIAL. IT MUST NOT BE INSTALLED UNDER ANY TYPE OF CEILING
OR OVERHANG. (see Fig. 9.1)
2. When shutting the unit down—be sure to TURN THE CONTROL VALVE FULLY OFF.
3. WARNING: CARBON MONOXIDE POISONING MAY LEAD TO DEATH. DO NOT MODIFY THIS
OUTDOOR FIREPIT OR ITS CONTROLS, EXCEPT AS PROVIDED FOR IN THIS MANUAL. Any other
change may be dangerous. Improper installation or use of the outdoor firepit can cause serious
injury or death from fire, burns, explosions, or carbon monoxide poisoning.
4. Check state and local codes to determine if the outdoor fire pit is permitted in your locality
before installation.
Note: Nothing should be
FIG. 9-1
above the fire pit
36" clearance
From sides to
any combustible
constructions
The dimensions shown in Fig. 9.1 are MINIMUM CLEARANCES to maintain when you install this outdoor fire pit.
ALL SIDES of the enclosure opening must be AT LEAST 36" from any combustible side walls. The unit MUST NOT
BE installed under any type of ceiling or overhang.
Important: Be sure you have read and understand all safety precautions and warnings contained
in this manual.
BEFORE PROCEEDING, CAREFULLY READ ALL OF THE IMPORTANT SAFETY INFORMATION
CONTAINED IN THIS OWNER'S MANUAL, INCLUDING:
A.
Pre-installation and preparation safety guidelines
B.
Installation and safety guidelines
C.
Minimum clearance combustibles.
BE SURE THE GAS SUPPLY FOR THE UNIT IS TURNED OFF.
Note: when installing the unit to natural gas or household propane, you must have a gas-supply
line that has been installed by a qualified professional technician in accordance with all local codes.
Refer to the PARTS LIST when installing the unit.
LOCATION
While following all requirements and safety information in this manual, locate the unit on a flat, level
surface.
CONNECT TO A PROPANE CYLINDER GAS SUPPLY
Important: Before installation, be sure the propane cylinder is turned off.
IMPORTANT SAFTEY INFORMATION
If not installed and used correctly per these instructions,
this product can cause serious injury.
MINIMUM CLEARANCE TO COMBUSTIBLES
36" clearance
From sides to
any combustible
constructions
BE CAREFUL
Minimum Clearance to Combustible Construction:
NOTE: NOTHING SHOULD BE ABOVE THE FIRE PIT
36" clearance between sides to any combustible
construction
Clearance to combustible construction:
Side walls: 36" from edge of top ring (Figure 9.1)
Ceiling: Nothing should be above the fire pit.
Flooring: 0"- can be installed on deck, slab, floor, etc.
INSTALLATION
11