Maintenance And Cleaning - Mestra IRIS 2 Manual De Instrucciones

Ocultar thumbs Ver también para IRIS 2:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English
4. To shift from a display to the other press the
key.
5. At the right of the display, you will see
lighting the icons of the functions that are
going to work.
6. Put the mixing ingredients into the bowl (D).
Pre-mix the products in the bowl manually
with a spatula or by activating the function
PRE-MIXING.
7. Use gentle pressure to position the bowl and
the mixer connection (F) with a good sealing.
8. Press the START/STOP
to start a cicle.
9. Upper display will show the blades speed.
10. Lower display will show the remaining time
to finish the work. Notice that the rest of the
fuctions will be added to the mixing time.
11. Use the vacuum meter (B) to check the
vacuum in the bowl. If there is no vacuum in
the bowl, move it gently to improve its
seating. Keep hold of the bowl until the
meter needle moves and the cup keeps
holded. You may now release the bowl.
12. During mixing operations, the needle must
remain in the "VACUUM" section. When the
pre-set time has elapsed, the unit will stop.
13. At the right of the display, the icon of the
function running will blink. Already done
functions will keep lighting.
14. Use the vacuum drain valve (C) to remove
the bowl from the unit. The mix is now ready
to be used.
15. To stop the operation of the unit at any
moment keep the START/STOP
pressed.
IMPORTANT
This machine has a "diaphragm" vacuum pump
(free of maintenance). If the unit is started at
very low room temperature, the membrane
rubber may not be sufficiently elastic for best
operation. Thus we recommend that the mixer
be run for approximately 1 minute before starting
operations in cold environments.
SAVED CONFIGURATIONS
The
Iris
2
Advanced
configurations saved in memory:
10
key for the unit
key
has
the
following
P1
- Mixing with spin inversion.
P2
- Pre-mixing type 1.
- Mixing with spin inversion.
- Turbo for 5 seconds.
P3
- Pre-vacuum for 5 seconds.
- Pre-mixing type 1.
- Mixing with spin inversion.
- Turbo for 5 seconds.
P4
- Pre-vacuum for 5 seconds.
- Pre-mixing type 1.
- Mixing with spin inversion.
- Turbo for 5 seconds.
- Post-vacuum for 5 seconds.
USING THE DOSAGES STORED IN THE
MEMORY
• To use a configuration stored in the memory,
press the P key as many times as required to
select the program you want (P1, P2, P3 or
P4).
• Press the key to display the values stored.
• Press the START/STOP
working.
NEW CONFIGURATION STORING
The electronic controls of the Iris 2 Advanced
allow
you
to
store
configurations. To store a configuration, proceed
as follows:
• First of all, select the configuration you want
to store, as explained in previous sections.
• Once you have selected the values you want
to store, select the program (P1, P2, P3 or
P4) in which you want to store the
configuration by pressing the P key as many
times as required.
• Finally, keep the P key pressed for a few
seconds. The display will flicker once to
indicate that the values have been stored in
the memory.

MAINTENANCE AND CLEANING

For best reliability and a long service life, we
recommend the following:
Clean the mixing bowl carefully each time it
is used. This will prevent dirt building up and
seizure of the blade shaft. Make sure the
bowl seat and joint are cleaned for a
complete sealing.
Keep the unit and the surroundings clean.
Do
not
use
inflammable products.
key and start
up
to
4
different
solvents
or
any
other

Publicidad