General Safety Precautions; Product Description; Technical Characteristics; Installation - Roger FIFTHY Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12
1

General safety precautions

Warning: incorrect installation may cause
severe damage or injury. Read the
instructions carefully before installing the
product.
This installation manual is intended for qualified personnel only.
ROGER TECHNOLOGY cannot be held responsible for any damage
or injury due to improper use or any use other the intended usage
indicated in this manual.
Installation, electrical connections and adjustments must be
performed by qualified personnel, in accordance with best
practices and in compliance with applicable regulations. Before
installing the product, make sure it is in perfect condition.
Disconnect the mains electrical power before performing any
work. Also disconnect any buffer batteries used.
Only use original spare parts when repairing or replacing products.
The packaging materials (plastic, polystyrene, etc.) should not be
discarded in the environment or left within reach of children, as
they are a potential source of danger.
2

Product description

FIFTHY is a flashing warning lamp unit connectable to ROGER
TECHNOLOGY control units.
3

Technical characteristics

FIFTHY/24
FIFTHY/24/OR
MAINS POWER VOLTAGE 24 Vac/dc
MAX MAINS POWER
6,5 W
ABSORPTION
OPERATING
TEMPERATURE
DEGREE OF
IP55
PROTECTION
N.B.: the FIFTHY flashing lamp unit is assembled with thermosonic
bonding technology to ensure an extremely high protection rating.
In the event of breakage or malfunction, do not attempt to repair
the flashing lamp unit and contact the customer support service
or your dealer of choice.
4

Installation

• Ensure that the surface onto which the FIFTHY flashing lamp
unit is to be installed is level, clean and not subject to vibration.
• Choose the mounting position: Figure 2 - top mounting
position; Figure 3 - lateral mounting position.
• Drill the mounting surface with a maximum bit size of 6 mm.
• Assemble the flashing lamp unit with the cable housing base
(A) at the bottom, as shown in fig. 2, or facing the wall, as
shown in fig. 3.
• Ensure that the cable passage and the mounting base are
sealed correctly if the mounting surface is not perfectly even.
• Make the electrical connections as shown in fig.4
(FIFTHY/230V - FIFTHY/230V/OR) or fig. 5-6 (FIFTHY/24V -
FIFTHY/24V/OR).
• If the FIFTHY/230, FIFTHY/230/OR is used, protect the device
with a F200mA (fast) fuse.
• Fasten the flashing lamp unit with the screws (B) and
commercially available anchor plugs (not included).
5

Operation

Turn on the power supply.
FIFTHY/230
FIFTHY/230/OR
230 Vac
115 Vac
4 W
-20°C
+55°C
IP55
Select the required flashing mode with the parameter 78 on the
control unit (except for H70/10CC - 11CC). This parameter is set
as 78 00 by default (flash frequency 1 Hz, 0.5 s on, 0.5 s off).
If required, set the pre-manoeuvre warning flash function with
parameter A5 (except for H70/10CC - 11CC).
6

Disposal

The product may only be uninstalled by qualified
technical personnel, following suitable procedures for
removing the product correctly and safely. This product
consists of numerous different materials. Some of these
materials may be recycled, while others must be
disposed of correctly at the specific recycling or waste
management facilities indicated by local legislation applicable for
this category of product. Do not dispose of this product as
domestic refuse. Observe local legislation for differentiated
refuse collection, or hand the product over to the vendor when
purchasing an equivalent new product. Local legislation may
envisage severe fines for the incorrect disposal of this product.
Warning! Some parts of this product may contain substances
that are harmful to the environment or dangerous and which may
cause damage to the environment or health risks if disposed of
incorrectly.
7
Additional
contact details
ROGER TECHNOLOGY is the exclusive proprietor holder of
all rights regarding this publication. ROGER TECHNOLOGY
reserves the right to implement any modifications without
prior notification. Copying, scanning or any alterations to this
document are prohibited without express prior authorised from
by ROGER TECHNOLOGY.
ROGER TECHNOLOGY CUSTOMER SERVICE:
business hours:
Monday to Friday
08:00 to 12:00 - 13:30 to 17:30
Telephone no:
+39 041 5937023
E-mail:
service@rogertechnology.it
Skype:
service_ rogertechnology
8

Declaration of Conformity

I the undersigned, as acting legal representative of the manufac-
turer
Roger Technology - Via Botticelli 8, 31021 Bonisiolo di Mogli-
ano V.to (TV)
hereby DECLARE that the appliance described below:
Description: Flashing light
Model: FIFTHY
Is conformant with the legal requisites of the following directives:
– 2014/30/EU; – 2014/35/EU; – 2011/65/CE
and that all the standards and/or technical requirements indi-
cated as follows have been applied:
EN 61000-6-3; EN 61000-6-2
Last two figures of year in which marking was applied | 16.
Place: Mogliano V.to
Date: 20/12/2016
information
and
Signature
9