G
B
DL1 - Programming activated (red)
DL2 - Stop contact (red)
DL3 - Barrier opening (green)
DL4 - Barrier closing (red)
DL5 - Photocells contact (red)
DL6 - Safety strip contact (red)
DL7 - Closing limit switch contact (red)
DL8 - Opening limit switch contact (red)
DL9 - Radio programming activated (green)
POINT C - MOTOR ROTATION DIRECTION CHECK
This check is meant to facilitate the installer during the start-up of the system or for any
other future controls:
1 - Turn DIP1 to ON, the red led DL1 starts blinking
2 - Press the PROG button and hold it (movement is now performed in "man present" mode,
open-stop-close-stop-open etc.).
If the GREEN led DL3 is on, the boom arm opens.
If the RED led DL3 is on, the boom arm closes.
3 - Turn DIP1 to OFF, the red LED DL1 turns off.
During Point C procedure the safety-strip and photocells are not enabled.
POINT D - TIME PROGRAMMING
1 - Close the barrier completely.
2 - Turn the DIP 2 to ON, the red led DL1 starts blinking.
3 - Press the PROG button, the boom arm opens.
4 - Once opening has been completed, the boom arm stops. The gap of time between now
(stop of the motor) and the next pressing of the PROG button (see step 5 below) will be
then stored as waiting time (max 5 minutes) for Automatic Closing feature.
5 - Press the PROG button, the boom arm closes and the Automatic Closing time is stored
(see DIP3 function to enable or disable the Automatic Closing feature).
6 - The red LED DL1 turns off.
7 - Turn DIP2 to OFF.
During Point D procedure, the safety devices (photocells and safety strip) are
active.
POINT E - RADIO CODE STORING (MAX 60 CODES)
1 - The boom arm must be completely closed.
2 - Turn DIP1 to ON position, the red LED DL1 starts blinking quickly
3 - Immediately, turn also DIP2 to ON position, the red LED DL1 starts blinking slowly. Each
code must be programmed within 10 seconds.
4 - Press one of the buttons on the remote control (usually channel A). If the remote control
is stored correctly green LED DL9 (on the PARK 230V CRX control board) emits a flash.
The 10 seconds' time within storing radio codes is automatically renewed to allow the
string of the next remote control.
5 - To end radio code storing either press PROG button or let 10 seconds pass. The LED
DL1 shall stop blinking.
6 - Turn DIP1 to OFF position.
7 - Turn DIP2 to OFF position.
RADIO CODE ERASING
1 - The boom arm must be completely closed.
2 - Turn DIP1 to ON position, the red LED DL1 starts blinking quickly
3 - Immediately, turn also DIP2 to ON position, the red LED DL1 starts blinking slowly. Code
erasing must be carried out within 10 seconds.
4 - Press the PROG button and hold it for 5 seconds, the total memory erasing will be
indicated by two flashes of the green LED DL9. The red LED DL1 will blink for 10
seconds and it will be possible to store new radio codes following the Point E procedure
described above.
5 - To end radio code storing either press PROG button or let 10 seconds pass. The LED
DL1 shall stop blinking.
6 - Turn DIP1 to OFF position.
7 - Turn DIP2 to OFF position.
RADIO CODE FULL MEMORY TEST
1 - The boom arm must be completely closed.
2 - Turn DIP1 to ON position, the red LED DL1 starts blinking quickly.
3 - Immediately, turn also DIP2 to ON position, the red LED DL1 starts blinking slowly. If the
green LED DL9 flashes six times, it means that the radio code memory is FULL (maximum
codes to be stored 60).
6 - Turn DIP1 to OFF position.
7 - Turn DIP2 to OFF position.
FUNCTIONING OF CONTROL ACCESSORIES in NORMAL MODE (DIP6 OFF)
ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE CONNECTED.
Make sure that any other type of command accessories (e.g. mass detectors)
used on the installation are set in the IMPULSIVE mode, otherwise, the gate will
be operated even without the protection of the safety devices.
OPEN1 BUTTON (COM - OPEN1)
The OPEN1 button performs the open command, regardless the position of the boom arm.
If the OPEN1 button is pressed during the closing, the boom arm stops and will reverse the
movement in opening. In PARK MODE (DIP6 ON), if there is a vehicle at the entry (see scheme
4) and the TLC contact is closed, the OPEN1 command opens the barrier. Otherwise, if the
TLC contact is open the OPEN1 command is disabled.
CLOCK FUNCTION
If you want the Clock Function must request PARK 230V with firmware 08 NOUP.
ATTENTION: A CLOCK CONNECTED TO PARK 230V with fw 05 or more ACTIVATES
THE OPENING MOVEMENT OF THE BARRIER WITHOUT HAVING THE PROTECTION
OF THE SAFETY DEVICES!
The Clock Function permits to keep the boom arm opened even if, for example, the Automatic
Closing is enabled (DIP3 ON) or somebody commands the barrier closing. It is useful during
rush hour, when traffic is heavy and the flow is low (e.g. entrance/exit of employees,
emergencies in residential areas or car parks) and it's necessary to keep the boom arm
opened.
CLOCK FUNCTION APPLICATION
It is necessary to request a PARK 230V control panel with firmware 08 NOUP. It can
be done by connecting a switch and/or a daily/weekly timer either in parallel to the OPEN1
button or instead of the OPEN1 button. When the control board receives this command,
the boom arm will open and by keeping this contact closed for all the time of the boom
arm opening, the Clock Function is automatically activated. In fact, once reached the open
position, the barrier will remain opened and all of the control board features are blocked.
Only when the OPEN1 button is released, the control board functions are re-activated and
the boom arm will close immediately.
CLOSE BUTTON (COM - CLOSE)
The CLOSE button performs the close command, regardless the position of the boom arm.
STEP BY STEP or AUTOMATIC COMMANDS (COM - K BUTT)
DIP5 - OFF => The K BUTT performs the cyclic command open-stop-close-stop-open etc.
DIP5 - ON => The K BUTT performs:
- the open command, if pressed with the barrier completely closed
- the close command, if pressed with the barrier completely opened
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is closing
REMOTE CONTROL
DIP4 - OFF => The REMOTE CONTROL performs the cyclic command open-stop-close-
stop-open etc.
DIP4 - ON => The REMOTE CONTROL performs:
- the open command, if pressed with the barrier completely closed
- the close command, if pressed with the barrier completely opened
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is closing.
AUTOMATIC CLOSING (DIP3 ON)
The Automatic Closing from the complete open position can be enabled turning ON the DIP3.
The maximum time that can be programmed is 5 minutes (see the Point D).
30