Technical Parameters; Indication Led - Elko EP PS3-100/iNELS Guia De Inicio Rapido

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13

Technical parameters

AC Input
Power supply:
Dissipated power:
Power load (apparent / active):
Power consumption at max. load
(apparent / active):
Protection:
DC Input
Power supply:
Protection:
Terminals for connecting the battery:
Automatic disconnect the battery:
Outputs
Output voltage 1:
Max. capacity:
Output voltage 2:
Max. capacity:
The overall effi ciency of resources:
Time delay after connecting
to the AC network:
Max. charging current:
LED Signalization
Output voltage 27 V OK (U
> 24 V):
OUT
Switch. power supply does not work
(does not oscillate):
Low output voltage (21 V < U
< 24V):
OUT
Output voltage 12 V OK (U > 11 V):
Overloading the power supply
(U
< 21 V):
OUT
Charging the battery (charging
current > 50 mA):
Output status
STATUS output 1 (U
OK):
PRI
STATUS output 2 (U
OK):
OUT
Output type:
Max. connectable voltage:
Max. current output:
Voltage drop on the switch max:
Other Data
Electric strength AC input - output:
The connection terminals:
Cable size (mm
2
):
Operating temperature:
Storage Temperature:
Working humidity:
Cover:
Overvoltage category:
Degree of pollution:
Working position:
Installation:
Execution:
Dimensions:
Weight:
Related standards:
TECHNICAL SUPPORT | E-mail: support@inels.com | Mobil: +420 778 427 366 | Tel.: +420 573 514 276, +420 573 514 211 | Fax: +420 573 514 227 | www.inels.com
Made in Czech Republic
PS3-100/iNELS
100 - 250 V AC / 50 - 60 Hz
max. 20 W
max. 13 VA / 2 W
max. 180 VA / 111 W
- safety fuse T3.15 A inside the unit
- electronic protection (short circuit current and thermal overload)
DC 24 V (two 12 V batteries in series)
- safety fuse F 6.3 A external
- electronic protection against current overload
- each battery separately
- separately routed extreme terminals (24 V)
- for the battery voltage < 21 V
- when exceeding discharge current 4.2 A
27.6 V
3.6 A
12.2 V
0.35 A
about 88 %
max. 1 s
adjustable from 0.2 - 2.2 A
green LED U
OK
OUT
fl ashing red LED U
FAIL (if a battery is connected)
PRI
yellow LED U
LOW
OUT
green LED + 12 V OK
red LED OVERLOAD
yellow LED CHARGE
closed, when power supply works
(not blinking LED U
PRI
closed, if U
> 21 V (not lit red LED OVERLOAD)
OUT
open collector current limited
50 V DC
50 mA
at 10 mA ... 140 mV
at 30 mA ... 400 mV
at 50 mA ... 700 mV
4 kV
row
max. 1x 2.5, max. 2x 1.5 (swith sleeve max. 1x 1.5)
-20 °C ... +55 °C
-30 °C ... +70 °C
20 ... 90 % RH
IP20 device, IP40 mounting in the switchboard
III.
2
arbitrary, vertical is optimum
on the DIN rail EN60715
6-MODULE
90 x 105 x 65 mm
401 g
general: EN61204; safety: EN61204-7; EMC: EN61204-3
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech republic | e-mail: elko@elkoep.com

Indication LED

switching power supply works correctly
output voltage 27 V is correct (U
output voltage 12 V is correct
batteries are not recharged
switching power supply not working correctly - UPS mode
output voltage 27 V is correct (U
output voltage 12V is correct
batteries are not recharged
switching power supply works correctly
output voltage 27 V is correct (U
output voltage 12 V is correct
batteries are recharged
switching power supply not working correctly - UPS mode
low output voltage 27 V (21 V < U
output voltage 12 V is correct
batteries are not recharged
switching power supply works correctly
low output voltage 27 V (21 V < U
output voltage 12 V is correct
batteries are not recharged
switching power supply works correctly
output voltage 27 V is correct (U
low output voltage 12 V (short-circuit, overload)
batteries are recharged
switching power supply is overload
low output voltage 27 V (U
low output voltage 12 V
FAIL)
batteries are not recharged
Warning
Before the device is installed and operated, read this instruction manual carefully and
with full understanding and Installation Guide System iNELS3. The instruction manual is
designated for mounting the device and for the user of such device. It has to be attached
to electro-installation documentation. The instruction manual can be also found on a
web site www.inels.com. Attention, danger of injury by electrical current! Mounting and
connection can be done only by a professional with an adequate electrical qualifi cation,
and all has to be done while observing valid regulations. Do not touch parts of the
device that are energized. Danger of life-threat! While mounting, servicing, executing any
changes, and repairing it is essential to observe safety regulations, norms, directives and
special regulations for working with electrical equipment. Before you start working with
the device, it is essential to have all wires, connected parts, and terminals de-energized.
This instruction manual contains only general directions which need to be applied in a
particular installation. In the course of inspections and maintenance, always check (while
de-energized) if terminals are tightened.
> 24 V)
OUT
> 24 V)
OUT
> 24 V)
OUT
< 24 V)
OUT
< 24 V)
OUT
> 24 V)
OUT
< 21 V)
OUT
OVERLOAD
U
LOW
OUT
U
OK
OUT
+12V OK
CHARGE
U
FAIL
PRI
OVERLOAD
U
LOW
OUT
U
OK
OUT
+12V OK
CHARGE
U
FAIL
PRI
OVERLOAD
U
LOW
OUT
U
OK
OUT
+12V OK
CHARGE
U
FAIL
PRI
OVERLOAD
U
LOW
OUT
U
OK
OUT
+12V OK
CHARGE
U
FAIL
PRI
OVERLOAD
U
LOW
OUT
U
OK
OUT
+12V OK
CHARGE
U
FAIL
PRI
OVERLOAD
U
LOW
OUT
U
OK
OUT
+12V OK
CHARGE
U
FAIL
PRI
OVERLOAD
U
LOW
OUT
U
OK
OUT
+12V OK
CHARGE
U
FAIL
PRI
2/2

Publicidad

Tabla de contenido
loading

Tabla de contenido