CAME MR8204 Guia De Inicio Rapido página 6

Detector de apertura y seguridad para puertas automáticas correderas
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
1
MOUNTING & WIRING
The door control unit and the door cover profi le must be correctly earthed.
2
RADAR FIELD - OPENING IMPULSE
MIN
1 x 0.5 m
3
INFRARED FIELD - SAFETY
0
1
2
2
3
3
2 m
Detection fi eld width indicated according to conditions defi ned in EN 16005 and including dimension of test body CA.
max.
5 cm
2.2 m
4 x 2 m
H
W
2
1
0
0
1
1
H
W
2.20 m
2.30 m
2.50 m
2.55 m
3.00 m
2.80 m
Check position of IR-curtains with
Spotfi nder and adjust if necessary.
DOOR
ORANGE
12-30 V DC
RELAY R1
1
RELAY R2
1
1
Output status when sensor is operational
2
For compliance with EN 16005, connection
to door controller test output is required.
MAX
2.2 m
The size of the detection fi eld varies according to the mounting height of the sensor.
@ 2.2 m:
Depth of curtain : 8-10 cm
Depth of safety fi eld: 25 cm*
* in standard presetting
GREEN
+
POWER SUPPLY
BROWN
-
YELLOW
OPENING INPUT
WHITE
OPENS DOOR
PINK
SAFETY INPUT
GREY
KEEPS DOOR OPEN
2
RED
+
TEST
BLUE
2
OUTPUT
-
2.2 m
fi eld size: max
GREEN
LED
RED
LED
CLOSER
CLOSER
AWAY
AWAY

Publicidad