EXAMPLE AUTOMATION TWO MOTORS WITH LATERAL INSTALLATION
INSTALLATION OF THE LATERAL FIXING PLATES
Place the fixing plates L motor
support to the door as illustrated.
L1
M1
Place and fix the motors on the fixing plates so that they are in line with the broaching
arms at a distance between 50 and 100 mm downwards by taking as reference the
attachment pin of the existing arm (fig 2). Insert the two spacers into the upper fixing
screw and lock with the nuts (fig 3). Insert the transmission tubes in the motor shaft
and in the broaching arms (straight or curved) and make 8mm holes. Insert the
elastic plug to block the tubes. Insert the elastic plug to block the tubes (fig 6).
LIMIT SWITCH ADJUSTMENT
MANUAL RELEASE
In case of lack of electric power, the
motor can be manually unlocked with the
lever by performing a rotation of about
90°. T o block bring back the release lever
to its original position.
Apply the external lock (OPTIONAL) to
unlock the motor from the outside in case
of power failure.
L2
M2
Limit switch C
Microswitch
Locked
Transmission tube
Broaching arm
Screw of the
limit switch
Unlocked
Elastic
plug