VIEW OF TYPICAL AUTOMATION AND NAMES OF COMPONENTS

5
Optimal installation
1- Operator
2- External photocell
3- Flashing warning light
4- Antenna

TECHNICAL DATA

Max. weight of gate
Max. width of gate
Motors power supply
Motor power
Motor RPM
Condenser
Mechanical unlock for emergency manoeuvre
Working temperature
weight
Protection rating
Opening time 90°
Force of thrust
motor current input
2
1
8
3
7
1
5
5- Internal photocell
6- Electronic control unit
7- Key-switch
8- Remote control
24V
24 Vdc
50 W
1800
/
With key
-20° C / +55° C
3 A
4
6
2
230V
500 Kg
2,50 mt
230 Vac
280 W
1400
12,5 µF
10 Kg
IP 67
16 sec
250 Nm
1.4 A

Publicidad