Comunello QUAD - 24V - 1M Instrucciones De Uso Y De Instalacion página 19

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
Menu 2 and then press the SELECT key to select blinking LED L5 and
then press the SET key: LED L5 becomes steady on and programming will
be completed. Repeat the procedure if you wish to restore the previous
configuration.
6. FLASHING LIGHT OPERATION
The control unit is factory set with Flashing Light during Pause Time
disabled. If you wish to enable this function, proceed as follows: make
sure you have enabled Extended Menu 2, press the SELECT key to select
blinking LED L6 and then press the SET key: LED L6 becomes steady on
and programming will be completed. Repeat the procedure if you wish to
restore the previous configuration.
7. ALWAYS CLOSE
The control unit provides the facility to set "Always Close" operation: this
function, which is programmable only if a Pause Time has already been
programmed, is activated after a power loss; if the gate open condition
is confirmed a closing movement is started automatically, preceded by
5 seconds of preflashing. If you wish to enable the function, proceed as
follows: ensure you have enabled Extended Menu 2 and then use the SEL
key to select blinking LED L7 and press the SET key; at the same time LED
L7 becomes steady on and the operation will be completed. Repeat the
procedure if you wish to restore the previous configuration.
EXTENDED MENU 3
The control unit is factory set to allow direct selection exclusively of the main
menu functions.
If you wish to enable the functions described in Extended Menu 3, proceed
as follows: select blinking LED no. 8 and press SET 3 times. The LED will
start blinking alternately 1 1 1 0 1 1 1 0 1 1 1 0. This means there is a
period of 30 seconds to select the functions in Extended Menu 3 using the
SEL and SET keys and then, after a further 30 seconds, the control unit will
revert to the main menu.
EXTENDED MENU 3
level
L1
1
L2
2
L3
3
L4
4
LED 1 + LED 2 +LED 3 +LED 4
L5
5
LED 1 + LED 2 +LED 3 +LED 4 +LED 5
L6
6
LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6
L7
7
LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6 + LED 7
LEV
MENU
DECELERATION FORCE ADJUSTMENT:
Operator force during the deceleration stage can be programmed on the
control unit. You can select one of 7 different power levels as follows; ensure
you have enabled Extended Menu 3; each combination of lit LEDs defines
a level as shown in the above table; in practice, starting from the bottom
LED (LED 1) and proceeding upward, each additional LED corresponds to
a higher power level. Use the SEL key to scroll through the different power
levels; for each selected power level the top LED will blink (for example,
selecting level 4, LED 1 + LED 2 + LED 3 will be steady on, while LED 4 will
blink); press SET to confirm. Factory setting: level 3 selected.
RESET:
If it becomes necessary to reset the control unit to restore the factory
settings, press the SELECT and SET keys together; this will cause all the
RED indicator LEDs to light simultaneously followed immediately by the
control unit switching off
DIAGNOSTICS:
Photocell Test:
The control unit is prearranged for connection of safety devices in
compliance with standard EN 12453 point 5.1.1.6. At each operating
cycle a functional test of the connected photocell is performed. In the case
of an open circuit and/or malfunctioning of the photocell, the control unit
does not enable movement of the gate and visually signals the test failed
condition by causing all the indicator LEDs to blink simultaneously. As soon
as correct operation of the photocell is restored the control unit is ready for
normal use. This operating mode guarantees failure mode monitoring in
compliance with EN 954-1 Category 2
LED 1
LED 1 +LED 2
LED 1 +LED 2 +LED 3
3 FLASHIES
Commands input test:
In correspondence with each low voltage command input the control unit
is equipped with an indicator LED so that the status of the input can be
checked at a glance. Operating logic: LED on input closed, LED off input
open.
COMUNELLO ®Copyright 2014 - All right reserved
19

Publicidad

Tabla de contenido
loading