CLEANING
To maintain the appearance and increase the service life, clean your
induction range daily.
WARNING
Electrical Shock Hazard
Do not spray water or cleaning products. Liquid could contact
the electrical components and cause a short circuit or an
electrical shock.
CAUTION
Burn Hazard
Heating surface remains hot after equipment is turned off. Hot
surfaces and food can burn skin. Allow the hot surfaces to cool
before handling.
TROUBLESHOOTING
Problem
The display is flashing.
The range turned off after 10
minute(s).
The range is on, but not heating.
The display is flashing F2.
The display is flashing F9.
The range suddenly stopped working.
SERVICE AND REPAIR
Serviceable parts are available on Vollrath.com.
To avoid serious injury or damage, never attempt to repair the unit or replace a damaged power cord yourself. Do not send units directly to
The Vollrath Company LLC. Please contact Vollrath Technical Services for instructions.
When contacting Vollrath Technical Services, please be ready with the item number, model number (if applicable), serial number, and proof of
purchase showing the date the unit was purchased.
WARRANTY STATEMENT FOR THE VOLLRATH CO. L.L.C.
The warranty period for Ultra Series induction ranges is 2 years.
This warranty does not apply to products purchased for personal, family or household use, and The Vollrath Company LLC does not offer a written
warranty to purchasers for such uses.
The Vollrath Company LLC warrants the products it manufactures or distributes against defects in materials and workmanship as specifically
described in our full warranty statement. In all cases, the warranty runs from the date of the end user's original purchase date found on the receipt.
Any damages from improper use, abuse, modification or damage resulting from improper packaging during return shipment for warranty repair will
not be covered under warranty.
For complete warranty information, product registration and new product announcement, visit www.vollrath.com.
The Vollrath Company, L.L.C. Headquarters
1236 North 18th Street
Sheboygan, Wisconsin
53081-3201 USA
Main Tel: 800-624-2051 or 920-457-4851
Main Fax: 800-752-5620 or 920-459-6573
Canada Customer Service: 800-695-8560
Tech Services: techservicereps@vollrathco.com
www.vollrath.com
Might be Caused By
There is not a pot/pan on the induction
range.
There is not a pot/pan on the induction range
The induction range turned off. This is
normal.
The cookware may be too small or may not
be induction-ready.
The overheat-protection feature may have
activated.
The pot/pan is not induction ready
The range may be too close to an external
heat source or the air intake may be
restricted.
Pujadas
Ctra. de Castanyet,
132 P.O. Box 121
17430 Santa Coloma de Farners
(Girona) – Spain
Tel. +34 972 84 32 01
info@pujadas.es
©
NOTICE: Do not use abrasive materials, scratching cleansers or
scouring pads to clean the equipment. These can damage
the finish.
1. Press and release
2. Unplug the cord from the wall outlet.
3. Allow the equipment to cool.
4. Wipe the exterior with a clean damp cloth.
5. Thoroughly wipe off any mild soap or chemical cleaners.
NOTICE: Residue could corrode the surface of the unit.
Course of Action
Place an induction-ready pan on the induction range.
Place an induction-ready pan on the induction range.
Make sure the pot/pan is induction ready. See the Function and
Purpose section of this manual.
Remove cookware. Let cooking surface cool.
Make sure the pot/pan is induction ready. See the Function and
Purpose section of this manual.
Relocate the range away from any external heat source. Clear
any obstructions to the air intake.
Vollrath of China
Vollrath Shanghai Trading Limited
Room 201, Building A
Xin Yi Plaza
1618 Yi Shan Road
Shanghai, 201103
China, P.R.C.
Tel: +86-21-5058-9580
2018 The Vollrath Company L.L.C.
to turn off the range.
Vollrath de Mexico S. de R.L. de C.V.
Periferico Sur No. 7980 Edificio 4-E
Col. Santa Maria Tequepexpan
45600 Tlaquepaque, Jalisco | Mexico
Tel: (52) 333-133-6767
Tel: (52) 333-133-6769
Fax: (52) 333-133-6768
Part No. 351662-1 ml
8/24/18