Perform Operational Test No. 1
A
Set the 2 or 3 pole switch or circuit breaker to
the ON position .
Start the water flow through the heater by
B
starting the process or fixture this heater is
connected to in order to activate heater .
When flow rate reaches approximately 0 .5gpm
(1 .9 lpm), the flow switch recognizes this
condition and begins the heating process .
When the flow switch activates:
• The display changes from OFF to the output
temperature, verifying power supply connection
C
to the heating elements via the triac switches .
• Element load lights may be solid or flash
in unison as heating elements modulate
depending on the hot water demand .
• Digital temperature controller shows water
temperature . Additional programming is
not necessary .
9
Perform Operational Test No. 2
A
Turn on hot water faucet/fixture/process . The
heater should activate immediately .
If the water flow exceeds maximum heating capacity of the heater, the temperature of water at the outlet may be lower
than the temperature selected on the controller. See table below to determine maximum temperature rise capabilities.
Models 208V, 240V, 277V, 480V
HL05
HL06
HL10
HL15
HL18
HL25
Models 208V, 240V, 277V, 480V
HL05
HL06
HL10
HL15
HL18
HL25
Bradley • 215-1823 Rev. F; ECN 18-17-017
Temperature Rise (GPM & F°)
1 gpm
1 .5 gpm
2 gpm
kW
ΔT °F
ΔT °F
ΔT °F
5
34
23
17
6
41
27
20
10
68
45
34
15
102
68
51
18
122
82
61
25
171
114
85
Temperature Rise (lpm & C°)
3 .8 lpm
5 .7 lpm
7 .6 lpm
kW
ΔT °C
ΔT °C
ΔT °C
5
19
13
6
23
15
11
10
38
25
19
15
57
38
28
18
68
46
34
25
95
63
47
Ensure the cover is on or enclosure door is
closed prior to performing this operational test.
Press the up or down arrow keys to
D
adjust the set temperature . The controller
displays the temperature of water
measured at the outlet .
Test water temperature and stability at
E
outlet by viewing the display . Controller
displays (in red) the temperature of water
exiting the heater .
Heater will not energize heating elements
if the inlet water temperature is equal to
or greater than the temperature set on the
digital controller .
Each model has precise specifications
for temperature rise capabilities.
Turn off hot water faucet/fixture/process .
B
The flow switch will deactivate and shut
off power to the heater .
2 .5 gpm
3 gpm
3 .5 gpm
ΔT °F
ΔT °F
ΔT °F
27
23
20
41
34
29
49
41
35
68
57
49
9 .5 lpm
11 .4 lpm
13 .3 lpm
ΔT °C
ΔT °C
ΔT °C
9
15
13
11
23
19
16
27
23
19
38
31
27
3/29/2018
HL-Series Tankless Heater
4 gpm
5 gpm
6 gpm
ΔT °F
ΔT °F
ΔT °F
17
26
31
43
34
28
15 .1 lpm
18 .9 lpm
22 .7 lpm
26 .5 lpm
ΔT °C
ΔT °C
ΔT °C
9
14
17
24
19
16
7 gpm
ΔT °F
24
ΔT °C
13
13

Publicidad