EN
2. INSTALLATION AND COMMISSIONING
Long enough and strong ropes should be attached to thehandle before the first use.
When the pump is immersed into the liquid, the rope along with a handle can be used to
balance the pump.
Installation
The equipment requires an area of at least 60x60cm.
Depth of equipment immersed in technical parameters.
When installing the equipment, make sure the open will not the suction opening will not
be blocked by foreign objects to keep the equipment stable.
Set toggle switch
1. A change-over switch is a device that can be steplesslyadjust- ed. For this, you
first need to loosen the screws. The position control height of the switch water
can be set by stepless adjust- ing the length of the power line.
2. Please check the following items before the pump startsrun- ning:
3. A float switch must be installed so that it is easy to switchbe- tween the ON
and OFF switching points. This should be checked, and the floating switch
should be carefully picked up and put down again. When you do this, pay
attention to the switching status of the switch.
4. Ensure the distance between the top of the floating switch and switch line card
buckle is not too small. If the distance is too small, it cannot guarantee normal
work.
5. When you set up the float switch, make sure that the switch does not touch the
base before the pump is opened. Warning: There is a risk of dry running.
6. Set the switch to automatically control the height of the water level by adjusting
the position of the float switch cable at the card line.
7. Please check the following items before the pump startsrun- ning:
8. The float switch must be clamped at the card line so that it can normally float,
control, turn on and off. This should be checked, and the floating ball switch
should be carefully picked up and put down again. When you do this, pay
attention to the switching status of the switch.
9. Ensure the distance between the top of the floating switch and switch line card
buckle is not too small. If the distance is too small, it cannot guarantee normal
work.
10. When you set up the float switch, make sure that the switch does not touch the
base before the pump is opened. Warning: There is a risk of dry running.
Risk for equipment damage!
Do not lift the pump by cable or
pressure hose,be- cause these cables
or pressure hoses are not designed for
ATTENTION!
tensile strength from pump weight.
The float switch must be able to move
freely and the submersible pump cannot
be used in a dry environ- ment.
Attention!
For rope handling: Do not operate
the pump without the pressure hose
to prevent the pump from twist-
ing around its longitudinal axis. In
continuous use of a pump with a rope,
the condition of the rope must be
checked periodically, as it may break
with increasing use time.