PREVENTATIVE MAINTENANCE continued
1.
Always store the jack in a well protected area where it will not be exposed to inclement weather, corrosive vapors, abrasive dust, or any
other harmful elements. The jack must be cleaned of water, snow, sand, grit, oil, grease or other foreign matter before using.
2.
The jack must be lubricated periodically in order to prevent premature wearing of parts. A general purpose grease must be applied to the
threads on the extension screw. Do not lubricate any portion of the lift saddle and make sure the saddle is free from grease, any kind of
lubricant, or debris before using the jack.
3.
It should not be necessary to refill or top off the reservoir with hydraulic fluid unless there is an external leak. An external leak requires
immediate repair which must be performed in a dirt-free environment by qualified hydraulic repair personnel who are familiar with this
equipment. Authorized Service Centers are recommended. IMPORTANT: In order to prevent seal damage and jack failure, never use
alcohol, hydraulic brake fluid, or transmission oil in the jack. Use Chevron Hydraulic Oil AW ISO 32 or its equivalent Unocal Unax AW 150.
4.
Every jack owner is responsible for keeping the jack label clean and readable. Use a mild soap solution to wash external surfaces of the
jack but not any moving hydraulic components.
5.
Do not attempt to make any hydraulic repairs unless you are a qualified hydraulic repair person that is familiar with this equipment.
MAINTENANCE
Important: Use only a good grade hydraulic jack oil. Avoid mixing different types of fluid and NEVER use brake fluid, turbine oil,
transmission fluid, motor oil or glycerin. Improper fluid can cause premature failure of the jack and the potential for sudden and immediate
loss of load.
Adding Oil: With saddle fully lowered and pump position fully depressed, set jack in its upright, level position. Remove oil filler plug (#16).
Fill until oil is level with the filler plug hole, re-install oil filler plug (#16).
TROUBLESHOOTING
PROBLEM: JACK WILL NOT LIFT RATED LOAD
POSSIBLE CAUSE: Release valve not tightly closed
ACTION: Ensure release valve tightly closed
POSSIBLE CAUSE: Overload condition
ACTION: Remedy overload condition
POSSIBLE CAUSE: Air supply inadequate
ACTION: Ensure adequate air supply
PROBLEM: JACK BLEEDS OFF AFTER LIFT
POSSIBLE CAUSE: Release valve not tightly closed
ACTION: Ensure release valve tightly closed
POSSIBLE CAUSE: Overload condition
ACTION: Remedy overload condition
POSSIBLE CAUSE: Hydraulic unit malfunction
ACTION: Contact dealer/distributor where item was purchased
PROBLEM: JACK WILL NOT LOWER AFTER UNLOADING
POSSIBLE CAUSE: Reservior overfilled
ACTION: Drain fluid to proper level
PROBLEM: POOR LIFT PERFORMANCE
POSSIBLE CAUSE: Fluid level low
ACTION: Ensure proper fluid level
POSSIBLE CAUSE: Air trapped in system
ACTION:
Follow purging instructions under ASSEMBLY INSTRUCTIONS on page 3
PROBLEM: WILL NOT LIFT TO FULL EXTENSION
POSSIBLE CAUSE:
Fluid level low
ACTION: Ensure proper fluid level
KTI63228
4
07/10/14