BTL7-A/C/E/G501-M _ _ _ _ -P-S32/S115/KA _ _
Micropulse Transducer in a Profile Housing
6
Configuration with the Micropulse Configuration Tool
6.1
Value table for factory setting
Output gradient
Transducer
Rising
BTL7-A...
(output 1)
BTL7-G...
BTL7-C...
BTL7-E...
Falling
BTL7-A...
(output 2)
BTL7-G...
BTL7-C...
BTL7-E...
Tab. 6-1:
Value table for factory settings
NOTICE!
Interference in function
Configuration with the Micropulse Configuration Tool
while the system is running may result in malfunctions.
► Stop the system before configuration.
6.2
Micropulse Configuration Tool
The BTL7-A/C/E/G501-... transducer can be configured
quickly and simply on a PC using the Micropulse
Configuration Tool PC software.
The most important features include:
–
Online display of the current position of the magnet
–
Graphical support for setting the functions and curves
–
Display of information on the connected transducer
–
Selectable number formats and units for display
–
Resetting to factory settings is possible
–
Demo mode without having transducer connected
The PC software and associated
manual can be found in the Internet under
www.balluff.com.
14
english
Unit
Min. value
Null value
V
−0,5
V
−10,5
−10,0
mA
0
mA
3,6
4,0
V
+10,5
+10,0
V
+10,5
+10,0
mA
20,4
20,0
mA
20,4
20,0
6.3
With BTL7-A/C/E/G501-... transducers with connectors
(S32/S115), the communication box must be looped in
between the transducer and controller. The communication
box is connected to the PC via a USB cable.
Connection cable approx. 0.3 m with
S32 or S115 (female) connector
Fig. 6-1: Connecting the communication box with a connector
With a BTL7-A/C/E/G501-...-KA_ _ transducer, the
communication lines La, Lb and GND must be connected
to the USB communication box.
Fig. 6-2: Connecting the communication box with a cable connection
End value
Max. value
0
+10,0
+10,5
+10,0
+10,5
0
20,0
20,4
20,0
20,4
0
−0,5
−10,0
−10,5
0
4,0
3,6
Connecting the USB communication box
USB cable
8-pin
8-pin
USB cable
When reading or writing data via the
Configuration Tool, both LEDs flash green.
Error value
+10,5
+10,5
20,4
3,6
−0,5
−10,5
0
20,4
3,6
Connection cable
approx. 0.3 m with
S32 or S115 (male)
connector
Controller
6-pin
Controller
Connection cable
approx. 0.6 m with
luster terminal