9 A 2-point regulation is performed in the first 30 minutes after the initial voltage supply.
2. Proceed with section 7.1 or 7.2 depending on the system configuration.
7.1

Teach-in without Alpha IP Access Point (stand-alone operation)

Keep a minimum distance of 50 cm between the devices for teaching-in.
The teach-in process can be interrupted shortly pressing the teach-in key again. This will be
confirmed by a red illumination of the device LED.
If no teach-in process takes place, the teach-in mode is automatically finished after 3 minutes.
1. Choose the channel through which the room control unit shall be taught-in, by a short press of the
Select key (B). Pressing 1x = HZ1 / Pressing 2x = HZ2.... Pressing 10x = HZ10
9 The corresponding LED of the heating zone flashes.
2. Press the System key (A) for 4 seconds, until the LED of the System key flashes rapidly in orange.
9 The teach-in mode for the selected channel is active for three minutes.
3. Press the System key of the room control unit for a minimum of 4 seconds in order to activate the
teach-in mode.
9 The device LED of the room control unit flashes in orange. You can find further information on this
in the corresponding manuals of the Alpha IP room control units.
The LED will light up in green after a successful teach-in process. The process must be repeated
if the LED lights up in red.
7.2

Teach-in of the room control unit to several heating zones

In rooms with several heating/cooling circuits, a room control unit can be taught-in to several heating/
cooling zones. For this, the teach-in process must be repeated with he same room control unit for the
additional heating zone (HZx) (see section 7.1).
7.3

Teach-in of the room control unit to several base stations

For a teach-in of a room control unit to several Alpha IP base stations, the base stations must be cou-
pled to each other first.
1. Press the System key (A) of the first base station for 4 seconds, until the LED of the System key
flashes rapidly in orange.
9 The teach-in mode is active for three minutes.
2. Press the System key (A) of the second base station for 4 seconds.
The LED will light up in green after a successful teach-in process. The process must be repeated
if the LED lights up in red.
9 The base stations are coupled.
3. A room control unit can now be taught-in to the heating zones of the second base station, as de-
scribed in section 7.1 / 7.1.1.
Commissioning