Safety Precautions - Sera PP Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 19
Cleaning
All parts can be cleaned with a brush and a neutral detergent.
Make sure no detergents get into the pond water when doing
so. Carefully rinse all cleaned parts with clean tap water before
you reassemble the pump and put it back into operation in the
pond. You can immerse the impeller unit (3.5) and the motor
block (3.3) in a decalcifier for stainless steel components if the
pump should have become strongly calcified. Please follow the
instructions for use of the decalcifier.
Maintenance
The mechanical components of the sera pond pumps PP can
be largely dismantled and replaced. The motor block (3.3) is en-
capsulated in plastics for electrical isolation and therefore can-
not be repaired.
Change the impeller unit (3.5):
First screw off the variable hose connector (3.2). Loosen the
screws (3.1.1) by a half turn with a screwdriver while simultane-
ously pressing them down. Then take off the upper half of the
pond basket (3.1.2). Loosen the screws of the holder (3.1.4) of
the pump. Remove the pump from the lower pump basket
(3.1.3).
Take the motor block out of the pump cover. Loosen the
4 screws that attach the holder plate (3.6) to the motor block
(3.3) with a Philips screwdriver. Take off the socket plate. You
can now pull the impeller unit (3.5) out of the pump and insert
the new impeller unit. Make sure the seals are correctly in place
when reassembling the unit.
Troubleshooting
Problem
No water delivery
Pump performance too low
Possible cause
Power supply interrupted
Cable defect
Motor block defect
Pump calcified, short circuit rotor unit
(3.5.2) seized up
Short circuit rotor jammed by sand
Pump draws in air
Pump cover clogged
Hose diameter too small
Variable hose connector not adapted
to hose
Hose too long
Pond filter clogged
Pond filter placed too high
Pump draws in air
Care of your pump during the winter:
Protect the sera pond pump PP from freezing! Remove the
pump from your pond in autumn. Clean and dry the pump com-
pletely (including the impeller unit) and very lightly grease all
metal parts. Important: To ensure optimal performance and life
span, clean the pump and store in a dry place if not in use and
do not leave it in water if switched off for longer periods. (If you
have used a material other than Vaseline for greasing you must
carefully remove it before using the pump again).

SAFETY PRECAUTIONS

• These pumps are not for use with swimming pools!
• sera pond pumps PP should be installed according to your
local electrical installation code. Please contact an electri-
cian.
• Always check that the motor connection and plug are intact
before using.
• Mains supply must correspond to the data on the type plate.
• The circuit to which the pump is connected must be secured
with a circuit breaker (FI / RCD ground fault interrupter,
30 mA).
• The electrical connection should be located in a moisture-
free area and should be at least 2 m (6.6 ft.) away from the
pond's edge.
• Keep the electrical connections dry!
• Never transport the pump by means of the electrical cord!
Possible solution
Plug in the plug, check fuse
Not repairable
Not repairable
Dismantle and decalcify pump
Dismantle and clean pump, change
position according to information for use
Remove leakage in the hose system
Pump is placed too closely underneath the
water surface and draws in air
→ place in a deeper position
Clean pump cover
Use hose with a larger diameter
Saw off too small diameters
Shorten hose
Clean pond filter
Place pond filter in a lower position, possibly
dig it in partially
Pump is placed too closely underneath the
water surface and draws in air
→ place in a deeper position
Remove leakage in the hose system
8

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pp 3000Pp 6000Pp 9000Pp 12000

Tabla de contenido