Detalle Del Cableado; Regulador Solamente - DoorKing 1838 Manual Del Propietário

Regulador programable del acceso de multi-puerta para uso con pc
Tabla de contenido

Publicidad

1838-065-G-12-06

2.3 DETALLE DEL CABLEADO

2.3.1

Regulador Solamente

30 Series Controller Detail Wiring
1
1
RS 232
Elevator
2
2
Connection
Control
3
3
4
7
16
5
6
14
+ 12 VDC
13
COMMON
11
DATA 1
12
DATA 0
11
16
10
+ 12 VDC
9
COMMON
12
8
DATA 1
7
DATA 0
6
5
4
NEG 12 VDC INPUT
POS 12 VDC INPUT
3
3
2
1
3
Relay 0
1 2 3
4
6
13
14
15
16
17
18
19
20
C.O.
PHN
2
1
16
Página
6
DATA 1
WHT
ELEVATOR
20
DATA 0
GRN
21
CONTROL
COMMON
BLK
22
2348-010
8
6
RED
BLK
WHT
GRN
CARD
RDR-1
6
RED
BLK
WHT
GRN
CARD
RDR-2
16 VAC
10
OUTPUT
BLK
12 VDC
RED
BATT
16 VAC
PWR
INPUT
4
9
17
RELAY 0 NORMALLY OPEN
RELAY 0 NORMALLY CLOSED
RELAY 0 COMMON
16 VAC
PWR
INPUT
4
5
17
RELAY 1 NORMALLY OPEN
RELAY 1 NORMALLY CLOSED
RELAY 1 COMMON
RELAY 2 CONTACT
RELAY 2 COMMON
13
Central Office phone line - touch tone, loop start.
1
A switch closure across terminals 4 & 6 will activate relay 1
2
for its programmed strike time.
Battery Backup - separate batteries required for phone
3
system and weigand terminals.
16 Volt, 20 VA UL Listed Transformer.
4
For 1837, use 16 Volt, 40 VA UL Listed Transformer.
5
Belden 9418 or Equivalent. If card reader is lighted, Belden
6
9931 can be used to provide extra wires for light power.
See Dwg No. M1835-065-5 for detail.
7
See Elevator Control Board Manual 2348-065 for detail.
8
Aux power transformer must be connected. Otherwise, RS232,
9
elevator control and weigand inputs will not function.
16 VAC output can be used to power lights on card readers that
10
have additional lighting for outdoor use.
Card reader connected to these terminals will operate Relay 1
11
for its programmed strike time.
Card reader connected to these terminals will operate Relay 2
12
for its programmed strike time.
Relay 2 contact is set N.O or N.C. with a jumper on the circuit
13
board.
Electric strikes are wired to Normally Open (N.O.) contacts;
14
magnetic locks are wired to the Normally Closed (N.C.) contacts.
Power for electric strikes or magnetic locks is not provided by the
15
system. Use a separate UL listed power supply.
Auxiliary and Elevator Control terminals are not available on the
16
1834 controller.
Use 18 AWG wire for runs up to 100 Ft. Use 16 AWG wire for
17
runs up to 200 Ft.
BASIC DOOR CONTROL
To Control
Relay
14
To Card
Reader Input
DOORKING, INC., INGLEWOOD, CA 90301
Title:
Detail Wiring - 30 Series Controller
Date:
7/04
Dwg. No.
LOCK
15
PWR
DOOR
LOCK
CARD
READER
B
M1835-065-2