WARNING AND CAUTIONS:
Description
Use the OPBCA adaptor when installing a Leviton powerbase
adaptor and low voltage ceiling/wall mounted sensor (such as OSCxx
or OSWxx models) in a Wiremold 4" square junction box (V5748-2)
on a hard ceiling, or in the opening of a mudring for a drop ceiling.
The OPBCA adaptor provides a finished look by filling in the spaces
at the corners and the unused holes.
Installation on a Hard Ceiling
WARNING:
1.
To avoid fire, shock, or death; TURN OFF POWER
at circuit breaker or fuse and test that power is off before wiring!
2. Pull line voltage wires through the opening of the junction box.
Dress wires to provide clearance in junction box when power base
adaptor is installed.
3. Partially thread the two #8-32 mounting screws provided with
the power base adaptor through mounting holes of the OPBCA
adaptor and into the mounting holes of the junction box
(refer to figure).
4. Connect wires per power base adaptor's installation guide.
5. Align the power base adaptor mounting holes and insert over
mounting screws.
6. Turn power base adaptor counter clockwise until it reaches
the stops.
7. Tighten the screws and begin occupancy sensor installation per
sensor's installation guide.
Installation in Drop Ceiling
WARNING:
1.
To avoid fire, shock, or death; TURN OFF POWER
at circuit breaker or fuse and test that power is off before wiring!
2. Attach the mudring to the junction box.
3. Pull line voltage wires through the opening of the junction box and
mudring. Dress wires to provide clearance in junction box when
power base adaptor is installed.
4. Partially thread the two #8-32 mounting screws provided with
the power base adaptor through mounting holes of the OPBCA
adaptor and into the mounting holes of the mudring
(refer to figure).
5. Connect wires per power base adaptor's installation guide.
6. Align the power base adaptor mounting holes and insert over
mounting screws.
7. Turn power base adaptor counter clockwise until it reaches
the stops.
8. Tighten the screws and begin occupancy sensor installation per
sensor's installation guide.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and
proper use for five years from the purchase date. Leviton's only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof
of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747. This warranty excludes
and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened,
abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for
a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment,
lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Cosmetic Adaptor
Cat. No. OPBCA
INSTALLATION
(10 cm.) x 5.76 cm (2.25")
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com
4" square x 2.25"
junction box
Boîte de 4 sur 4
sur 2,25 po
Caja cuadrada
de empalme 4"
OPBCA adaptor
Adaptateur OPBCA
Adaptador OPBCA
Powerbase adaptor
Base d'alimentation
Base de alimentación
del adaptador
Ceiling mount
occupancy sensor
Plafonnier-détecteur
de mouvements
Sensor de ocupación
de montaje en el techo
4" square x 2.25"
junction box
Boîte de 4 sur 4 sur 2,25 po
Caja cuadrada de empalme 4"
(10 cm.) x 5.76 cm (2.25")
Mudring/Cadre/Escayola
OPBCA adaptor
Adaptateur OPBCA
Adaptador OPBCA
Powerbase adaptor
Base d'alimentation
Base de alimentación
del adaptador
Ceiling mount
occupancy sensor
Plafonnier-détecteur
de mouvements
Sensor de ocupación
de montaje en el techo
DI-001-OPBCA-20A
English
Ceiling
Plafond
Techo
Drop ceiling
Plafond suspendu
Falso Techo