Operation
AC V measurement
In order to measure AC voltages greater than 0.6 V, rotate the selector switch (3) to the position ~V
and place the measurement probes on the test object. The multimeter automatically sets itself to the
most favourable measurement range.
In order to measure AC voltages of less than 600 Millivolt, rotate the selector switch (3) to the po-
sition mV. Here, by pressing the button Select (2), it is switched from DC to AC. At more than
600 mV, OL.is indicated on the display.
Range
Resolution
600 mV
0.1 mV
6 V
1 mV
60 V
10 mV
600 V
100 mV
DC V measurement
In order to measure DC voltages greater than 0.6 V, rotate the selector switch (3) to the position =V
and place the measurement probes on the test object. The multimeter automatically sets itself to the
most favourable measurement range.
In order to measure DC voltages of less than 600 Millivolt, rotate the selector switch (3) to the po-
sition mV. At more than 600 mV, OL.is indicated on the display.
Range
Resolution
600 mV
0.1 mV
6 V
1 mV
60 V
10 mV
600 V
100 mV
20
Accuracy
Impedance
>1000 MΩ
± 0.8 %
+3 digits
>10 MΩ
Accuracy
Impedance
>1000 MΩ
± 0.8 %
+2 digits
>10 MΩ
Overvoltage protection
250 VAC
RMS
600 VAC
RMS
Overvoltage protection
250 VAC
RMS
600 VAC
RMS
Testboy
Frequency
range
40 Hz~1 KHz
®
Pocket 100