Motion Sensor - NA-DE 10360 Guia De Inicio Rapido

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6
TS EN 60669-2-1
Complies with ROHS Regulation Directive
2002/95/EC
360° MOTION SENSOR
USAGE AREAS
• At the building entrances, stair vestibutes.
• At the long halls within the flats.
• At the places required within the flats.
• At covered parking lots.
• At the requisite locations within the hotels.
• At the schools, hospital and oil filing station.
"OFFERS ENERGY SAVING FEATURE''
GENERAL SECURITY CAUTIONS
• Take off the original package and control if there is any damage of transportation
and general view of the product.
• Do not use the product at cross purposes.
• Keep it away from water and moist areas.
• Do not use the product at dusty, dirty and rusty places.
• Do not supply high voltage.
• Do not apply any liquid.
• Protect from any stroke.
• Using 230-240V~ voltage is so dangerous that only the specialist
electricians must install and apply.
CAUTIONS FOR INSTALLATION AND USAGE
• Installing must be carried out professionally in accordance with applicable national wiring and
electrical operating conditions.
• Turn of the network before mounting.
• Do not mount the product near the radiator and moist areas.
• Place the product horizontal to the ceiling.
• Fix the bulbs before operating.
• Use 10A fuse the supply input.
• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.
• Setting can be made 10 - 15 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight settings abruptly.
• Do not make a second adjustment before you get a result from the first setting of the time
and daylight.
• After you determine the right setting of the daylight, you can arrange the time as you need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And that
you can find the correct setting for sensitivity incrementally.
• When a cleaning needed for the product, take of carefully and clean with a dry rag.
• Avoid mounting the detector close to objects that can cause rapid temperature changes such
as heaters, fans, refrigerators and ovents etc, and prevent the detector from point-blank
sunshine.
• It can cause the device operate inaccurately if there is tree, brushes etc. in the coverage area.
• The product should be mounted minimum 50 cm or more away from lamps or fluorescent
lamps.
• The detection range(diameter) of the ceiling type motion sensor models is 9m ± 1m. The
products are less effective for the narrow areas less than 9 m diameter. For narrow areas we
can recommend our 10464 model because it has distance settings.)
SPECIFICATIONS
Operating voltage
230-240V~ 50/60 Hz
Angle of coverage
360°
Height
2.8 m.
Width
9 m.
Time setting
5 sec. ± 1 sec. / 5 min. ± 10 sec.
Lighting load
Max 1000W incandescent
Max 400W fluorescent
Protection class
IP20
Opr. temperature
-20 °C ~ +40°C
Detection range is determined at the temperature of +20°C
SETTING
(e)
(e) Daylight setting
The sensor's response threshold can be infinitely varied from 2-2000 lux.
If you turn the knob clockwise device will operate at dark.
Control dial set
= daylight operation approx. 2000 lux.
Control dial set
= night-time operation approx. 2 lux.
(f) Time setting
Light ON time can be adjusted continuously from
"5 sec. ± 1 sec. / 5 min. ± 10 sec." If you turn the knobn clockwise device will operate at minimum
time. (10 seconds)
Control dial set to min = Shortest time (5 sec. ± 1 sec.)
Control dial set to max = Longest time (5 min. ± 10 sec.)
NOTE: Device will automatically make its own offset by checking environment for approximately
5 minutes after the first installation. After this period device will operate normally. If you think
the device does not operate normal in first installation, please wait for 5 minutes and start to
test again. Be sure that there is no motion by this period.
‹stanbul Deri Organize Sanayi Bölgesi Tufle Sok. No:8
M1-8 Özel Parsel 34953 Tuzla / ‹STANBUL - TÜRK‹YE
www.na-de.com.tr
10360
10360
CLASS II
max
min
info@na-de.com.tr
N
L
N
LS
DETECTING RANGE
4.5 m.
SYSTEM COMPONENTS
(a) Protection cover
(b) Screw places which seperate
ceiling mounting item.
(c) Ceiling mounting item.
(d) Mounting places to ceiling.
(e) Time-daylight adjusting
knob.
(f) Cable entry - connection place.
TROUBLESHOOTING
MALFUNCTION
CAUSE
• Lamp is off
• Daylight adjustment set to
night-time mode during daytime
operate
• Bulb faulty or there is no
connection
• Power switch off or no electricity
• Fuse faulty
• There is no
• Fuse switch off or fuse faulty
electricity on the
device
• Connection faulty.
• Continuously
• Continuously movement in
lamp is on
detection zone
• Cars on the streets are being
detected.
• Wind, rain, snow is moving to the
trees & bushes or open windows in
detection zone.
• Change perception
• Sudden temperature changes due
area in device
to weather(wind, rain, snow) or the
air expelled from fans.
• Different ambient temperatures.
DETECTION AREA
Detection area of motion sensors depends on the angle between PIR detector and moving
direction, temperature , mounting style and mounting place. Temperature is very important for
operation for motion sensor like all electronic devices. Using higher value of loads written on
manuals and packages will decrease temprature inside the device when using Na-De Motion
Sensor. As a result detection range will decrease and may cause defect of electronic components.
Environment temperature will also cause decrease of detection range. Detection range give is
determined at +20°C. If the weather is hot, it will decrease.
Walking targential to the sensor
(normal detection range)
The maximum detection range can be realized when walking tangential to the sensor (figure1)
When walking directly to the sensor detection range will be low. Because you will not be able
to cut vertical areas. Detection range of The detection distace of 10360 model is 9 m as diameter
and 4,5 m as radius.
GUARANTY
We will remedy defects caused by material flaws or manufacturing faults. The warranty will be
met by repair or replacement at our own discretion. The warranty shall not cover damage to
wear parts, damage or defects caused by improper treatment or maintenance. Further
consequential damage to other object is excluded.
Claims under the warranty will only be accepted if the unit is sent fully assembled and well
packed complete with a brief description of the fault, a receipt or invoice ( date of purchase
and dealer's stamp) to the appropriate Service Center.
(L) Line (phase) conductor
(N) Neutral conductor
(LS) Lamp conductor
360°
4.5 m.
9 m.
f
b
d
e
c
d
SOLUTION
• Control daylight setting and
re-adjust
• Fit the bulp into the lamp holder,
if it still does not operate, change
the bulb.
• Check the electricity and power
on.
• Change the fuse.
• Check the fuse if necessary use
a new fuse.
• Check the connection cables.
• Check the detection zone.
• Avert it is being detection.
• Change detection zone, change
site of installation.
• Change site of installation or
keep the reasons away.
• Change site of installation.
Walking directly to the sensor
(lower detection range)
Figure 1
KK-10360_150416_GLB_00
GB
a

Publicidad

Tabla de contenido
loading

Tabla de contenido