CONTENTS
IDENTIFICATION OF PART "B"
AND "BV"
1.
2.
8.
7.
6.
Series B is a line of hot air generators with direct heating system
that mix the heat released externally with combustion residues.
These heaters are particularly suitable to be used for heating,
defrosting and drying both outdoors and in areas with frequent
air exchanges.
Series BV is a line of hot air generators with indirect heating
system. These generators have a heat exchanger that enables
to separate exhaust combustion gases from the heat released in
the environment, so that it is possible to inject a fl ow of clean hot
air in the area that needs to be heated and to discharge exhaust
fumes externally.
Series B and BV hot air generators are designed in compliance
with current safety, performance and life standards, are fi tted
with safety devices confi gured to guarantee continuous
operation, minimize noise and are manufactured in carefully
selected materials that ensure maximum reliability.
Heaters can be fi tted with wheels to simplify handling or ceiling-
mounted. Their excellent standalone performances along with
the possibility of using a thermostat guarantee utmost fl exibility
during use. The external indicator, which measures the quantity
of fuel in the reservoir, enables to quickly check whether the
reservoir needs refi lling.
SAFETY INFORMATION
WARNING
7
7
7
8
8
8
8
9
9
10
10
1. Hot air
output, 2. Flue
connection, 3.
3.
Upper shell,
4. Fan guard,
5. Reservoir
4.
cap with fuel
level probe, 6.
Power cable,
7. Control pa-
nel, 8. Lower
5.
IMPORTANT: Read the manual carefully before attemp-
ting to assemble,switch on or service this heater. The use
of the heater may cause serious or fatal injuries resulting
from burns, fi re, explosion, electrical discharge or carbon
monoxide poisoning.
DANGER:Carbon monoxide poisoning can be fatal!
Carbon monoxide poisoning The fi rst symptoms of carbon
monoxide poisoning are similar to those of fl u, with headache,
dizziness and/or nausea.These symptoms may be caused by
the defective functioning of the heater. Go outside into the open
air immediately! Have the heater repaired. Some people feel
the effects of carbon monoxide to a greater extent, especially
pregnant women, those suffering from anaemia, cardiac or lung
conditions, those who are drunk and anyone at a high altitude.
Ensure that you have read and understood all the warnings.
Keep this manual for future reference - it is a guide to the safe
and correct functioning of the heater.
• Use only fuel oil no.1 in order to avoid the risk of fi re or explo-
sion. Never use petrol, naphtha, paint solvents, alcohol or other
highly infl ammable combustibles.
• Fuelling
a) The individual responsible for fuelling the heater must have
the relevant competence and be completely familiar with the
manufacturer's instructions and with current norms concer-
ning the safe fuelling of the heaters.
b) Only use the type of fuel expressly specifi ed on the identifi ca-
shell
tion label of the heater.
c) Before adding fuel, extinguish all fl ames, including the pilot
light, and wait until the heater has cooled down.
d) While adding fuel, inspect all the fuel lines and joins to make
sure there are no leaks.
Any leak whatsoever must be repaired before switching on
the heater.
e) In no circumstances must more than one day's supply of
fuel be stored in the same building in proximity to the heater.
Fuel storage tanks must be kept in a separate location.
f) All fuel tanks must be kept at a minimum distance from hea-
ters, oxyacetylene torches, welding equipment etc. (with the
exception of the fuel tank incorporated into the heater) fol-
lowing regulations.
g) Wherever possible, fuel should be stored in a place where
the fl oor does not allow fuel to seep through and drip onto live
fl ames beneath, which might cause fi re.
h) Fuel must be stored in compliance with current norms.
• Never use the heater anywhere where petrol, paint solvents or
other highly infl ammable vapours are present.
• While using the heater, follow all local ordinances and current
norms.
•
Heaters
used
tains
or
tuated
at
It
is
also
These materials should be fi xed safely so as to ensure that
they do not catch fi re and are not blown by the wind.
• Only use in locations where there are no infl ammable fumes or
high concentrations of dust.
• Power the heater only with electric power that has the voltage,
frequency and number of phases specifi ed on the identifi cation
label.
HOT AIR GENERATOR
in
the
proximity
other
covering
materials
a
safe
distance
following
recommended
to
use
7
GB
of
tarpaulins,
cur-
must
be
si-
regulations.
fi reproof
materials.