1. Disconnect the appliance and remove the cover.
2. Drain the tank.
3. Disconnect the AC adapter from the appliance (see under the appliance).
4. Put a tablespoon of citric acid (lemon juice) and 100 ml of hot water (temperature
above 70°C) in the tank. You can also replace the lemon juice with 4 tablespoons of
white vinegar in 100 ml of hot water.
5. Leave it to work for 5 minutes and empty the tank once again.
6. Dry the tank with a dry cloth without touching the membrane.
ATTENTION
- Do not dry the membrane with a dry cloth, because this can damage it.
- Do not use acids, enzymes or detergents to clean the air humidifier. This may give off
toxic gas or cause malfunctions.
- Never clean the appliance when it is running or connected to the mains. Be sure to
disconnect the device during cleaning.
CAUTION
- The use of essentials oils with the Humidoo® is limited to 2/3 DROPS OF ESSENTIAL
OILS PER 100 ML OF WATER.
- To maintain an optimum quality level of this product, please clean it after EVERY 5/6
USES OR 2/3 DAYS OF USE, especially if you use essential oils and/or very hard water.
A different use and maintenance from the above-mentioned instructions may lead
to damages on the product, for which Visiomed® cannot be held responsible for. No
exchange will be done if the membrane of the air humidifier is damaged.
Frequently asked questions :
- What product can be used to clean the air humidifier membrane ?
A: Mild detergent (without solvent or abrasive), slightly acidic detergent (1 to 3 drops,
diluted in 100 ml of water), white vinegar or citric acid (lemon juice).
- What must I do if my water is very hard ? If scale builds up ?
A: If you find scale on the membrane, we advise you to clean it with a cotton swab,
moistened with one of cleaning products recommended in this manual. If your
water is very hard, we advise you to clean your appliance more regularly, so you do
not allow it to become scaled.
- What product should not be used for cleaning the membrane ?
A: NEVER use abrasive product (scouring cream, baking soda, etc.), solvents (90°
alcohol, bleach, ammonia, etc.).
18
VM-H3- User Manual- 072017
VI. TECHNICAL CHARACTERISTICS
- Dimensions : Approx. 110 x 154 mm
- Weight : Approx. 315g
- Power supply : Input : AC100~240V 50/60Hz Output : DC24V650mA
- Length of cable : Approx. 150 cm
- Absorbed power : Approx. 10 W
- Timer Mode : 60/180/360 min/continuous
- Water tank capacity : 300 ml
- LED light : 6 bulbs
- Materials : Top parts in PP, base in ABS
- Accessories : AC adapter and graduated container
- Misting method : Vibrations by ultrasound at approximately 2.4 MHz
VII. TROUBLESHOOTING GUIDE
Refer to the table below if the appliance operates abnormally :
SYMPTOMS
POSSIBLE CAUSES
Does not switch on quickly
Is there enough water in
the reserve ?
Is the power cable connected
properly ?
No mist or abnormal mist
Not enough water ?
Too much water ?
Membrane fouled by
scale ?
Are the cover and the
inside cover badly placed ?
Is the air intake hole under
the base fouled ?
VM-H3- User Manual- 072017
SOLUTIONS
Add water to the tank.
Disconnect, examine the
cable, and then reconnect
with precaution.
Add an adequate quantity
of water in the reserve.
The water should never
exceed the limit of 300 ml
(max).
Consult the instructions
for CLEANING AND MAIN-
TENANCE.
Remove the covers, and
then replace them correctly
to allow the propagation of
the steam.
Remove any dust from the
air intake : A restricted air
flow will affect the mist
quality.
19