Installation
1

Install Unit

Rough-in of plumbing lines and wall braces must be
completed before unit can be properly installed.
Remove Access panel and with
A
the help of another person, place
unit in position against wall .
B
Ensure unit is level, shimming floor unit if
necessary . Mark the wall anchor locations .
2
Connect Water Supply to Valve Assembly
WARNING! Do not turn on water until
Step 4 is completed!
Connect stops to hot and cold water supply .
A
Connect one end of each supply hose to a
stop and the other end to the hot and cold
inlets of the Navigator
Bradley • 215-1073 Rev. M; ECN 17-00-002
Water Supply
Gang Valve
Assembly
Navigator TMV
TMV .
®
OPTIONAL TEMPERED LINE CONNECTION: Connect
B
stop to supply . Connect one end of the supply hose to the
stop and the other end to the tempered line adapter in the
gang valve assembly .
C
Red Tube
(to Aerator)
Green Tube
(to Aerator)
Black Tube
(to Aerator)
(S01-526)
Cold Supply Inlet
8/21/2017
SN2003, SN2023 - Infrared
Install suitable wall anchors (supplied
by installer) for 3/8" bolts at the marked
locations . Secure unit to wall .
Water Supply
Gang Valve
Assembly
OPTIONAL
Tempered
Line Adapter
Assembly
(S39-804)
Braided
Hose
Stop Valve
Hot Supply Inlet
5