PROGRAMMING PROCEDURE (parameter setting)
• All the functions of the electronic programmer can be set in the Display menu "LCD1" using the three buttons contained therein:
- use the arrows to navigate through the menu and/or to adjust the display contrast;
- use "PROG/OK" to modify the parameter settings and/or to confirm.
T B
F I
PROGRAM
F S
CP
T B
F I
00.000.001
F S
CP
FW_10
OPTIONS
OK
"PROG/OK" to confirm
SEQUENTIAL COM.
OPEN-SHUT/
OPEN-STOP-SHUT
"PROG/OK" to set
AUTO-RECLOSING
ON/OFF
"PROG/OK" to set
PRE-FLASHING
ON/OFF
"PROG/OK" to set
WARNING LIGHTS
FIXED/
INTERMITTENT
"PROG/OK" to set
(1)
INDICATOR LIGHT
FIXED/
INTERMITTENT
"PROG/OK" to set
(2)
PHOTOCELL INVERT
DURING CLOSING/
AND IN STOP
Note:
"PROG/OK" to set
1) The indicator light flashes slowly during opening, rapidly during closing;
remains lit when the boom is blocked but not completely closed and is off
(3)
TEST FI
when the boom is completely closed.
ON/OFF
2) FI Mode:
"PROG/OK" to set
- FI also active when the boom is blocked: If the photocells are in alarm and
(3)
the boom is blocked, no movement commands will be accepted (even
TEST FS
ON/OFF
opening commands);
"PROG/OK" to set
- FI active only during closing
In both cases activating the FI safety device during the closing stage will
MEMO RADIO
force travel direction inversion.
ON/OFF
3) Photocell test (FI/FS)
"PROG/OK" to set
If you enable the security test you will have to connect both the transmitter
and the receiver to the controlled load output (CTRL 24 Vdc). When the
LC/CH2 OUTPUT
RADIO CHANNEL/
test is enabled one second will pass between receiving a command and
COURTESY LIGHT
carrying it out.
"PROG/OK" to set
4) Current sensor settings:
- Level 1 = motor electrical input + 2 amps
EXIT
OK
- Level 2 = motor electrical input + 2.5 amps
"PROG/OK" to confirm
- Level 3 = motor electrical input + 3 amps
BACK TO OPTIONS
- Level 4 = motor electrical input + 4 amps
- Level 5 = motor electrical input + 5 amps
The programmer checks the electrical input to the motor, detecting any
eventual increase in effort above the normal operating limits and intervenes
as an additional safety device.
SAFETY DEVICES
OK
"PROG/OK" to confirm
TB CONTACT
NC/8K2
"PROG/OK" to set
FI CONTACT
CURRENT SENSOR
NC/8K2
"PROG/OK" to set
FS CONTACT
NC/8K2
"PROG/OK" to set
CP CONTACT
NC/8K2
"PROG/OK" to set
EXIT
OK
"PROG/OK" to confirm
BACK TO SAFETY DEVICES
20
MOTION
OK
"PROG/OK" to confirm
MOTOR SELECTION
SLi924ESB 700kg
SLi924ELB 1000kg
"PROG/OK" to set
(4)
LEVELS 1...5
"PROG/OK" to set
EXIT
OK
"PROG/OK" to confirm
BACK TO MOTION MENU
DISPLAY
OK
"PROG/OK" to confirm
CONTRAST
OK
"PROG/OK" to set
ADJUST CONTRAST
0...63
"PROG/OK" to confirm
REAR LIGHTING
ALWAYS ON/
60 SEC./30 SEC.
"PROG/OK" to set
EXIT
OK
"PROG/OK" to confirm
BACK TO DISPLAY MENU