‡ :KHQ LQVWDOOLQJ 3HHUOHVV ZDOO PRXQWV RQ FLQGHU EORFN YHULI\ WKDW \RX KDYH D PLQLPXP
RI   PP RI DFWXDO FRQFUHWH WKLFNQHVV LQ WKH KROH WR EH XVHG IRU WKH FRQFUHWH
anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, gener-
DOO\   PP PLQLPXP IURP WKH VLGH RI WKH EORFN &LQGHU EORFN PXVW PHHW $670 &
VSHFL¿FDWLRQV ,W LV VXJJHVWHG WKDW D VWDQGDUG HOHFWULF GULOO RQ VORZ VHWWLQJ LV XVHG WR GULOO WKH
hole instead of a hammer drill to avoid breaking out the back of the hole when entering a
void or cavity.
‡ $OZD\V DWWDFK FRQFUHWH DQFKRUV directly to load-bearing concrete.
1
Drill holes and insert anchors (E).
2
3ODFH SODWH A) over anchors (E). Secure with screws (D). Tighten screws.
WARNING
wall plate
SODVWHU
dry wall
wall plate
SODVWHU
dry wall
D
WARNING
A
5 of 51
CORRECT
concrete
INCORRECT
concrete
concrete
E
E