Operating Instructions
assembly
SySTem SeTUp
PLEASE REFER TO AIR TOOL AND SPRAY
GUN SET-UP (IN170102AV) FOR AIR
SYSTEM HOOK-UP INSTRUCTIONS.
Use of a whip hose
prevents accidental
triggering of tool when pressurized air
is connected to system.
Using fittings or air hoses which are
too small can create a pressure drop
which will result in a loss of power in
tool.
nOTe: Do not install a quick coupler
set between tool and whip hose.
aIr TOOL SeTUp
aLL mODeLS
Ensure tool is not connected to air
supply then place tool upside down on
workbench.
Never carry a tool
by the hose or pull
hose to move tool or a compressor.
Keep hoses away from heat, oil and
sharp edges. Replace any hose that is
damaged, weak or worn.
pre-Operation
LUbrICaTIOn
Air tools require lubrication through-
out the life of the tool. Proper
lubrication is the owner's responsibility.
Use Campbell Hausfeld airtool oil (Part
No. ST127000AV) to lubricate, clean
and inhibit rust in one step. Failure to
lubricate and maintain air tool properly
will dramatically shorten the life of the
tool and will void the warranty.
This air tool
requires
lubrication before initial use and
before and after each additional use.
1. Disconnect tool from air supply.
2. Turn die grinder upside down.
3. While pulling trigger, pour a
teaspoon of Campbell Hausfeld oil
in the air inlet.
Cover exhaust port
with a towel before
applying air pressure. Oil will discharge
through exhaust port during first few
seconds of operation after an airtool
has been lubricated. Failure to cover
exhaust port can result in serious
injury.
www.chpower.com
4. Release trigger and connect air tool
to air supply. Cover exhaust port
with a towel then run air tool for
20 to 30 seconds. Oil will discharge
from exhaust port when air
pressure is applied. Continue to run
die grinder until no oil is discharg-
ed. Wipe all residual oil off of tool
before use.
Operation
aTTaChmenTS
Disconnect air tool
from air supply
before changing attachments or
serious injury could occur.
1. Insert stem of grinder attachment
into collet opening (See Figure 1).
Make sure stem is fully inserted.
Grinder
Attachment
Collet
figure 1
Nut
2. Securely tighten collet with
wrenches (supplied with some
models) (See figures 2 & 3).
figure 2 - Wrenches
To Tighten
Collet Turn
Wrench To The
Right
Always Turn This
Wrench In The
Opposite
Direction
figure 3
Apply one wrench to the collet nut
and the other to the spindle. Turn
the wrench on the collet nut to the
right, simultaneously turning the
other wrench in the opposite
direction. Make sure stem does not
slip out of position.
2
3. Do the opposite of Step 2 to loosen
and change the grinder attachment.
Make sure attach-
ment stem is fully
inserted into collet opening and collet
is securely tightened. Loose attach-
ments could fly off during operation
and cause serious injury. Only use
attachments rated for a minimum of
25,000 RPM.
Storage
The air tool must be lubricated before
storing. An air motor cannot be oiled
too often.
Disconnect air tool
from air supply
before lubricating.
1. Turn grinder upside down.
2. While pulling trigger pour a
teaspoon of Campbell Hausfeld oil
in air inlet.
Cover exhaust port
with a towel before
applying air pressure. Oil will discharge
through exhaust port during first few
seconds of operation after an airtool
has been lubricated. Failure to cover
exhaust port can result in serious
injury.
3. Connect die grinder to air supply
and cover exhaust port with a
towel. Run die grinder for only 2 to
3 seconds because more oil needs to
remain in the air tool when storing.
Technical Service
For information regarding the
operation or repair of this product,
please call 1-800-543-6400.
replacement parts
Information
For information regarding where to
order replacement parts, call toll free
1-800-543-6400. Please provide the
following information:
• Model number
• Stamped-in code
• Part number and description
Address parts correspondence to:
Campbell Hausfeld
Attn: Parts Department
100 Production Drive
Harrison, Ohio 45030 U.S.A.