COMMANDER SE PARAMETER DESCRIPTION
PAR.
01
02
03
04
05
06
07
08
09
10
Changing Parameter 10 to L2 allows access to level 2 parameters from 11 to 54.
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
*51
*52
*53
*54
*Only become active when parameter 29 is set to "br.Eu" or "br.US" & stop/reset button is pressed for 1 second.
4
LEVEL 1
Minimum speed (Hz)
Maximum speed (Hz)
Acceleration rate (s/100Hz)
Deceleration rate (s/100Hz)
Speed reference select
Rated current (A)
Rated speed (rpm)
Rated voltage (V)
Power factor
Parameter access
LEVEL 2
Preset 1 (Hz)
Preset 2 (Hz)
Preset 3 (Hz)
Preset 4 (Hz)
Jog speed (Hz)
Current input mode (mA)
Enable negative preset speeds
Last trip
Trip before Par.18
Trip before Par.19
Trip before Par.20
Load display units (%/A)
Speed display select units (Hz/rpm/units)
Customer scaling for parameter 23
Security setup
FWD/REV key enable
Power up mode for keypad ref.
Parameter cloning mode
Load defaults
Ramp mode
Stopping mode
Variable torque select
Spinning motor select
Positive logic select
Start / Stop logic setup
Analogue output select
Switching frequency
Auto tune
Rated frequency (Hz)
Number of poles
Serial mode
Baud rate
Serial address
Software version
Fieldbus node address
Fieldbus baudrate
Fieldbus diagnostics
Voltage mode selector
Low frequency voltage boost
Motor thermistor select
Zero speed threshold
Motor current threshold
Motor current threshold hysteresis
Brake release delay time
www.controltechniques.com
DEFAULT 50 / 60 Hz
0.0
50.0
/
60.0
5.0
10.0
A1.A2
PAd
/
drive rating
1500
/
1800
/
230/400
230/460
0.85
L1
0.0
0.0
0.0
0.0
1.5
4 - .20
OFF
--
--
--
--
Ld (%)
Fr (Hz)
1.00
0
OFF
0 (zero speed)
no (do nothing)
no (defaults not loaded)
1(standard ramp)
1(ramp to stop)
OFF
OFF
On (positive)
0
Fr (motor speed)
6kHz
0 (no auto tune)
50.0
/
60.0
Auto
0 (ANSI)
4.8
1.1
--
0
0
0
3
3.0
OFF
1.0
0
0
0
Commander SE Quick Start
Issue Number: 2