TECHNICAL DATA

BATTERY
CHARGER
.....12 V, 14,4 V, 18 V
Voltage range ........................................
............................3 A
Quick charge current .............................
........................500 mA
Maintaining charge current ....................
..........................30 min
Battery charging time with 1.5 Ah ..........
..........................60 min
Battery charging time with 3.0 Ah ..........
........................704 g
Weight according EPTA-Procedure 01/2003
WARNING! Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric
shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Do not dispose of used battery packs in the household refuse or by
burning them. Milwaukee Distributors offer to retrieve old batteries
to protect our environment.
Only the following battery packs can be charged with this charger:
voltage
battery
rating
No. of
(of storage battery)
battery
cells
12 V
C12 B
≤ 1.5 Ah
12 V
C12 BX
≤ 3.0 Ah
2 x 3
12 V
M12 B
≤ 1.5 Ah
12 V
M12 BX
≤ 3.0 Ah
2 x 3
14.4 V
C14 B
≤ 1.5 Ah
14.4 V
C14 BX
≤ 3.0 Ah
2 x 4
14.4 V
M14 B
≤ 1.5 Ah
14.4 V
M14 BX
≤ 3.0 Ah
2 x 4
14.4 V
M14 B4
≤ 4.0 Ah
2 x 4
18 V
C18 B
≤ 1.5 Ah
18 V
C18 BX
≤ 3.0 Ah
2 x 5
18 V
M18 B
≤ 1.5 Ah
18 V
M18 BX
≤ 3.0 Ah
2 x 5
12 V
M12 B2
≤ 2.0 Ah
12 V
M12 B4
≤ 4.0 Ah
2 x 3
18 V
M18 B2
≤ 2.0 Ah
18 V
M18 B4
≤ 4.0 Ah
2 x 5
18 V
M18 B5
≤ 5.0 Ah
2 x 5
Do not try to charge non-rechargeable batteries with this charger.
Do not store the battery pack together with metal objects (short
circuit risk).
No metal parts must be allowed to enter the battery section of the
charger (short circuit risk).
Never break open battery packs or chargers and store only in dry
rooms. Keep dry at all times.
The battery clamps of the charger are fed by the mains supply. Do
not touch the tool with conducting objects.
Never charge a damaged battery pack. Replace by a new one.
Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
This appliance is not intended to be
used or cleaned by persons with
reduced physical, sensory or mental
capabilities, or lack of experience or
knowledge, unless they have been
given instructions concerning the safe
use of the appliance by a person
legally responsible for their safety.
They should be supervised whilst
using the appliance. Children shall not
8

ENGLISH

use, clean or play with this appliance,
which when not in use should be
secured out of their reach.
SPECIFIED CONDITIONS OF USE
This charger charges 12V, 14.4V and18V Milwaukee Li-Ion battery
packs.
Do not use this product in any other way as stated for normal use.
MAINS CONNECTION
Connect only to single-phase AC current and only to the system
voltage indicated on the rating plate. It is also possible to connect
to sockets without an earthing contact as the design conforms to
safety class II.
TRANSPORTING LITHIUM BATTERIES
Lithium-ion batteries are subject to the Dangerous Goods
Legislation requirements.
Transportation of those batteries has to be done in accordance
with local, national and international provisions and regulations.
• The user can transport the batteries by road without further
requirements.
3
• Commercial transport of Lithium-Ion batteries by third parties is
subject to Dangerous Goods regulations. Transport preparation
3
and transport are exclusively to be carried out by appropriately
trained persons and the process has to be accompanied by
4
corresponding experts.
4
When transporting batteries:
• Ensure that battery contact terminals are protected and insulated
to prevent short circuit.
5
• Ensure that battery pack is secured against movement within
packaging.
5
• Do not transport batteries that are cracked or leak.
Check with forwarding company for further advice
3
CHARACTERISTICS
5
After inserting the battery into the reception of the charger the
battery will automatically be charged (red control lamp is
illuminated continuously)
When a hot or cold battery pack is inserted into the charger
(fl ashing red lamp), charging will begin automatically once the
battery reaches the correct charging temperature (0°C...65°C). The
max. charging current is fl owing when the temperature of the
Li-Ion-battery is between 0°C and 65°C.
The battery's charging time is between 1 min and 30 min (at
1,5 Ah), depending on the state of discharge.
Once the battery is fully charged, the LED on the charger changes
from red to green.
It is not necessary to remove the battery after charging. The
battery can be stored permanently in the charger without the
danger of being overcharged.
If both LEDs fl ash alternately then the rechargeable battery is
either not fully pushed in or there is a fault with the battery or
charger. Take the charger and battery out of use immediately for
safety reasons and have them inspected by a Milwaukee customer
service centre.
Both 12V and 14.4/18V battery packs can be inserted into the
charger at the same time, but they will be charged one after the
other. The fi rst battery pack to be inserted will be the fi rst one to be
charged. The red LED for the second battery pack will fl ash slowly
to indicate that the charging process has not begun yet.
MAINTENANCE
If the supply cord of this appliance is damaged, it must only be
replaced by a repair shop appointed by the manufacturer, because
special purpose tools are required
Use only Milwaukee accessories and Milwaukee spare parts.
Should components need to be replaced which have not been
described, please contact one of our Milwaukee service agents
(see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the Article No. as well as the machine type printed on the
label and order the drawing at your local service agents or directly
at: Techtronic Industries GmbH, Max-Eyth-Straße 10,
71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before starting.
Do not burn used battery packs.
Do not dispose of electric tools together with household
waste material.
Electric tools and electronic equipment that have
reached the end of their life must be collected
separately and returned to an environmentally
compatible recycling facility.
Check with your local authority or retailer for recycling
advice and collection point.
Never charge a damaged battery pack.
Replace with a new one.
This tool is only suitable for indoor use. Never expose
tool to rain.
T3.15A
Anti-surge fuse 3.15 A
European Conformity Mark
Regulatory Compliance Mark (RCM). Product
meets applicable regulatory requirements.
EurAsian Conformity Mark.