3.5.1 TIG STD.
3.5.2. TIG PULSE.
3.5.3. PARAMETERS SETTING MODE. TIG PROCESSES.
P1: SELECT PROCESS
MOD Torch Mode
REF
Cooling unit mode
TPR
Gas pre-flow time
IS
Initial current
UPS
Up Slope
IB
Base Intensity
DCL
% Upper Intensity Bipulse
DWS Down Slope
IE
End crater current
TPS
Gas post-flow time
3.6. JOB RECORDING MODE.
3.6.1. LOAD JOB
P1: SELECT PROCESS
Note: if the message
GPS 3000/4000 C
E2: ADJUST WELDING CURRENT
E1: ADJUST FRECUENCY
P1: ENTER TO SETUP
E1: SELECT CYCLE PARAMETER
(2")
PARAMETER
RANGE
VAL-2T-4T
OFF-ON-AUT
0,0-5,0
10-100
0,0-10,0
10-100
20-80
0,0-10,0
10-100
0,0-10,0
P4 : BURN JOB
(2")
P4: ENTER TO JOB MODE
JOB
appear on display D1, this is indicative that there are not programs recorded.
E2: ADJUST WELDING CURRENT
E2: ADJUST VALUE
UNIT
RESOLUTION RESET
--
--
2T
--
--
OFF
Restrictions mode VAL 2T
s
0,1
0,3
%
1
30
s
0,1
0,4
%
1
50
%
1
50
s
0,1
0,6
%
1
30
s
0,1
0,4
E2: SELECT Nº JOB
E2: SELECT JOB
P1: SAVE PARAMETERS
(2")
STD
PULSE
4T
VAL
2T
4T
P4: SAVE JOB
(2")
D1: JOB SELECT
5 s
23