The appliance was designed to exhaust odors and vapors in the best way. The
appliance is to be installed on the outside wall of the house and connected to the
cooker-hood which is in the kitchen.
The motor must be installed in such a manner that its vibrations are not transmitted to
the conduits or structures of the building. Make sure the motor is firmly and stably secure
and that it is level.
WARNING! This motor must not be installed upside down. The fan should be installed
in such a manner that maintenance and repair operations can be carried out simply and
safely. Noise disturbance can be avoided by installing a silencer (Not included, but
available).
DUCTING:
Should be installed with a Ø150mm conduit, a different diameter will affect the
performance of the motor, reducing its suction capacity, increasing noise produced
as well as causing other problems.
The recommended length of the conduit between the hood and the motor is 6 m
maximum, a greater distance will reduce the motor's suction capacity, while a
shorter distance will increase the noise of the hood, if the latter case in inevitable,
we recommend the use of soundproofing elements.
It is recommended that the conduit from the hood to the motor has no sharp angles,
as they will reduce the suction capacity of the motor If they are inevitable, try to
ensure they are not too close to the inlet or outlet of the motor (at least 0.5m away).
Do not use elbow joints with an angle of less than 90º, or place one after another,
the minimum recommended distance between them is 1m, and try to make them as
open as possible.
The maximum total length of the conduit from the hood to the exterior should be 6
linear meters, not counting elbow joints (one elbow joint is equivalent to 1 linear
meter), any longer and the suction capacity of the motor will be reduced.
The material for the pipe has to be approved by an authorized company.
It is important to avoid changes in the diameter (we recommend a diameter of
150mm).
Sirius will not be responsible for problems of capacity and/ or noise level due to the
missed respect of the warnings included in the manual of instructions.
WARNING! Please read this user's manual carefully before installing the motor.
Before installing, check that the diameters of the fume outlet correspond to those indicated in the
specifications table.
Do not manipulate the internal connections in the motor box. Do not plug the motor directly into
the mains socket, it should always be connected through the hood, following the connection
instructions.