5.5.5. Multi-sensor main displays

NB: The measurement shown on the multi-
sensor display depends on the individual values. If
GB
a tare is performed on a sensor, it is reflected in the
display of the total value. A warning message warns the
user. The peak load function is not taken into account in
the display (actual value is maintained).
§5.5.5_a
When used with several sensors, two additional
displays are available to display the forces. These
screens are accessible by pressing the left and right
buttons.
B
C
K
L
A
Measurement
B
Tractel logo
C
Unit of measurement
D
Measurement filter (see 5.5.8.2)
E
Threshold trip filter (see 5.5.8.2)
F
Built-in buzzer (see 5.5.12)
G
Product battery indicator
H
Status of the connection to the sensor the furthest
away
I
Time
J
Identification of the sensor assembly
K
Values of set thresholds (see 5.5.12)
L
Warning message in case of a tare performed in an
individual sensor
NB: The tare and peak load functions are
available in exactly the same way as a single sensor.
The peak load function switches all the sensors to peak
load mode.
The second multi-sensor screen shows the values of
the sensors individually, as well as the total. The display
is dynamic and can contain up to four sensors.
10
E
D
F
G
H
J
C
D
O
A
A
K
A
Individual measurements of the sensors
I
B
Display of the total of the individual measurements
C
Tractel logo
D
Unit of measurement
E
Measurement filter (see 5.5.8.2)
F
Threshold trip filter (see 5.5.8.2)
A
G
Built-in buzzer (see 5.5.12)
H
Product battery indicator
I
Status of the connection to the sensor the furthest
away
J
Time
K
Sensor batteries indicator
L
Identification of sensor (designation + last nine digits
in serial number)
M
Sensor capacity in t
N
Values of set thresholds (see 5.5.12)
O
Measurement sign (null, positive or negative)
The screen can be navigated with the arrow buttons.
The selected sensor is highlighted.
The tare and peak load functions are accessible by
pressing the corresponding buttons when a sensor is
highlighted. It is not possible to activate the two modes
simultaneously. These modes apply to the total if no
sensor is selected.
NB: The display bars are not visible on this screen.
Pressing the "OK" button briefly changes the
measurement sign.
Holding down (for two seconds) the "OK" button on a
selected sensor takes you to the associated single-
sensor screen.
Holding down (for one second) the left button deselects
the sensor.
F
E
G
H
I
B
J
A
L
A
N
M