Safety Instructions

DANGER
Danger to life from electric shock when touching electrical installations!
► Wall mounting: before drilling holes, make sure that there is no electrical wiring in the wall.
► Pay attention to exposed wires if they are situated close to the installation location.
► Never work on antenna systems when a storm is approaching or during a storm.
► Make sure that earthing and lightning protection measures are carried out by a specially trained electrician.
Danger to life during installation/operating in improper ambient conditions!
► Wear a properly fitted and intact safety harness when working on a roof or in any other location where you are at risk of
falling.
► Make sure that the roof is able to carry your weight.
► Do not enter crumbling or unstable surfaces.
► Wear stable shoes with non-slip soles.
► Make sure that the roof and climbing aid are dry, clean and non-slip.
► Make sure that the antenna mast is earthed in accordance with DIN EN 60728-11.
CAUTION
Risk of suffocation due to small parts that could be swallowed!
► Keep any mounting material out of reach of children.
CAUTION
Risk of severe injuries from falling parts!
► If passers-by are at risk due to falling parts during installation, the area of risks must be cordoned off.
NOTICE
Risk of material damage due to incorrect supply voltage!
► Operate the antenna only at the permitted voltage of 5 – 25 V.
Setting up, Connecting and Commissioning
Attaching F-type Connector
Only use the enclosed F-type connectors. Do not use any tools to attach the F-type connectors, tighten them hand-tight.
NOTICE
Risk of short circuit!
Material damage due to contact between the wires of the braided shield and the inner conductor.
► When attaching the F-type connectors, make sure that there is no contact between the wires of the braided shield and
the inner conductor.
► Make sure that the inner conductor is not bent.
1. Put the weather shield cap onto the cable.
1. Remove 10 mm from the outer plastic jacket ①. Cut into it carefully not to damage the
braided shield ②.
2. Put the braided shield ② back.
3. Remove 7 mm dielectric and aluminium foil ③ from the inner conductor ④.
4. Screw the F-type connector ⑤ onto the end of the cable until it sits tightly.
5. Make sure that the inner conductor is exposed 2 mm max..