7

Filter status

The filter status is represented by the
filter LED:
■ OFF: Filter OK / No failure;
■ BLINKING: Order replacement
filter;
■ ON: Replace filter.
8

Malfunction alerts

LED 1
Menu item
HRU
initializing /
HRU service
mode
ERROR (all
LEDS are
blinking)
Initalisation /Service mode error: LED 1,
LED 2 and LED 3 are blinking. Air flow
cannot be set and there is no ventilation.
Check HRU display and HRU manual to
fix this error.
Error: Any other HRU or system
malfunction, all indicator LEDs on the
device are blinking. Check HRU display
and HRU manual to fix this error.
9

Installation

Disconnect the ventilation unit from the
main power before installing the device.
Always follow local safety regulations.
LED 2
LED 3
During assembly, ensure that ALL
screws are tight.
If ordered (fig 4.1 - 4.5):
1. Attach the wall-mounting casing I
with the plugs H and screws G to
the wall.
2. Fasten the wall frame A with the
screws (F) on the wall, wall-mounting
casing (I) or mounting plate (E).
3. Put the communication cable
through the design frame X and
resize window (D).
4. Plug in the communication cable
(fig 4.5), to connect the ventilation
unit and the device.
5. The cable requirements are:
■ 2x twisted pair, unshielded,
(preferably in compatible colours
with the colour coding of the
connectors);
■ Stiff (solid) wires (not flexible
type), for push-in clamps;
■ Specification according to DIN
VDE 0281: J-Y(St)Y 2 x 2 x 0,6.
6. Attach the device (B) (with the
design frame X and the resize
window D) with the screws E to
the frame A.
To replace, use any of the following
screws:
■ Hardened and galvanized steel
screw 2.2 x12 PT10;
■ M2.2x 12 cross recess plan
plas-fix45°.
7. Push the cover C into its place.

10 Commisioning

Turn ON the main power of the
ventilation unit. When the device first
starts, the LED 1, LED 2 and LED 3 are
blinking.
EN - 13