INSTALLATIoN MANUAL
PCV123D (DGM1D)
Desktop and Handheld Mifare
- A wireless connection with the reader (remove JP3 jumper). The wireless communication is
established between the reader and the terminal unit.
- Connection to a reader controller from the network system: The DGM1D is then switched
from a stand alone mode to a network mode programmable with a PCV123D (remove JP2
jumper). The relay output is disabled for the cardholders.
The same site code can be programmed on many controllers.
The site code can be changed with the PCV123D terminal unit via the RS232 or wireless
connection (JP1 jumper on).
The cardholder's badges can be enabled or disabled with the JP2 jumper.
PC software:
- Login name: supervisor
- Password: 1234
B - PCV123D TERMINAL UNIT fUNCTIoNNALITIES
The terminal unit has many purposes:
- Reads smartcard
- Manages the controllers via RS232 connection or wireless communication with reader
- Enrollment and identification of the cardholders badges and master keys
- Capability to manage the site from a PC
PCV123D unit
To switch ON the Terminal unit press on the power button located at the top right side. It
powers off automatically after 5 minutes if not being used.The numerical keys are used for
entering the values; and the « A » and « b » keys to enter hexadecimals values (A to F).
A, b, * and # keys can be used to scroll in the same sub-menu or on the display.
The C is the ENTER key and D is the ESCAPE/DELETE key. It is also possible to select the next
or previous menu with these keys.
PCV123D voltage specifications
The Terminal unit is powered with:
- 2 x AA batteries 1.5 V
- plug-in power supply: 9V @ 300 mA
To switch ON the Terminal unit press on the power button located at the top right side.
It powers off automatically after 5 minutes if not used.

Installation and wiring

The voltage on the controller is protected by a polyswitch fuse and a transil diode.
The input voltage can be done in AC or DC and polarity free.