LOCATION
For optimal performance, install the unit on the cold feed to the place where the water is
heated. This could be on the cold inlet to a combination boiler (A) or on the cold inlet to a
hot water cylinder (B).
INSTALLATION
•
Connect the main body of the unit to the pipe with the two tie wraps (C & D).
•
Loosely assembly the ferrite ring around the pipe using the thumbscrews and nuts (E).
•
When the ring is assembled, tighten the screws by hand (F).
•
Plug PSU into unit and connect to mains power (G).
ELECTRICITY
As with all electrical equipment, ensure that the equipment is connected in accordance with
current electrical regulations in your area.
TROUBLESHOOTING
The red light shows that the signal is being transmitted into the water - it should be bright.
If this is not the case check the following:
•
The ferrites should be assembled and the screws tight.
•
The mains supply should be on. Check that the PSU is fully plugged into the mains and
that the DC jack is fully plugged into the unit.
•
If fitting to metal pipework, avoid placing unit into an electrical loop (see below).
If the unit is fitted in a loop, move the unit to a location outside the loop.