About The Controls On The Dehumidifier - Gree GDN06AJ-D4EBC1A El Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ABOUT THE CONTROLS ON THE DEHUMIDIFIER

Controls
(GDN16AJ-K4EBC1A GDN12AJ-K4EBC1A
NOTE: When the bucket is full or removed, the
controls cannot be set.
ON/OFF Pad
Press to turn the dehumidifier on and off.
FILTER Pad
After 250 hours of operation, the Clean the
Filter indicator light will glow to remind you to
clean the filter. Remove the filter and clean it.
Press to turn off the Clean the Filter light. See
the Care and Cleaning section.
Humidity Set ControlPads
The humidity level can be set within a range
of 80% RH (Relative Humidity) to 35% RH
(Relative Humidity) in 5% reduce or at
CO for continuous operation.
NOTE: If CO (Continuous) is selected, the
dehumidifier will operate continuously at
its maximum dehumidification settings if
attached to a hose to drain or until the
bucket is full.
For drier air, press the - pad and set to
a lower percent value (%).
For damper air, press the + pad and set
to a higher percent value (%).
When you first use the dehumidifier, set
Other Features
BUCKET FULL Light
Glows when the bucket is ready to be emptied,
or when the bucket is removed or not replaced
in the proper position.
Alarm
If the bucket is full or missing for more than three
minutes, an alarm will sound for about 10 seconds
to remind you to empty and replace the bucket.
Auto Shut Off
The Water Level Control Switch shuts off the
dehumidifier when the bucket is full, or when
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.
4
High and Low fan
indicator lights
4 hour or 2 hour
delay on/off
indicator lights
Power On
indicator light
6
GDN06AJ-D4EBC1A)
3
Bucket full light indicates
bucket needs to be emptied
or it is not in the proper place
Clean the Filter
indicator light
2
5
1
the humidity control to 45% or 50%. Allow
at least 24 hours for the dehumidifier to
achieve the humidity level. If you still have
damper air than desired, set the humidity
level to a lower setting or select Continuous
for maximum dehumidification.
This unit has 3-min lag due to the device
for protecting circuit .In order to prolong
the compressor's working life, the compressor
will not start until the unit has run for 3 minutes.
Display
Shows the set % humidity level while
setting, then shows the actual (+/– 5%
accuracy) room % humidity level.
FAN SPEED
Controls the fan speed.
Press to select High or Low fan
speed.
Set the fan control to High for maximum
moisture removal. When the humidity
has been reduced and quiet operation is
preferred, set the fan control to Low.
TIMER Pad
If unit is turned on and running in timer mode
for 2hr or 4hr,can turn off the unit. When unit
stand by and running in timer mode for 2hr or
4hr can turn on the unit.
the bucket is removed or not replaced in the
proper position.
Auto Defrost
When frost builds up on the evaporator coils,
the compressor will cycle off and the fan will
continue to run until the frost disappears.
Power Outage
In the case of a power outage or interruption,
the unit will automatically restart, in the settings
last used, after the power is restored.
3
Continuous operation on
indicator light

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Gdn08aj-k4mbc1aGdn10aj-k4mbc1aGdn12aj-k4ebc1aGdn16aj-k4ebc1a

Tabla de contenido