ND 951-5 61-361 Test-Pro Instru
General Specifications:
Indicators: Continuity: (30Ω) indicated by a continuous
"beep" within 100 msec. Low Battery indicator displayed in the
LCD when battery is below operating range. Overrange: "OL"
displayed.
Environmental: Operating temperature 32°F to 122°F, storage
0°F to 140°F with batteries removed, RH<70%.
LCD: 3.5 digits.
Size: 4.0"W x 7.5"H x 2.5"D
Weight: 18 oz. including battery.
Battery life: >200 hours typical (9V NEDA 1604 type, JIS006P,
IEC6F22 battery).
Accessories: Comes with a pair of test leads ground lead with
clip, operator' s manual, and battery.
Overload Protection: 600V for DCV, ACV, and phase indica-
tion. 500VAC/500VDC for capacitance, ohms, frequency and
diode test. Current protected by 2A/600V (6.35mm x 25.4mm)
fuse model LA-3893 and 0.25A/500V (6.35mm x 32mm) fuse
model LA-3898.
Auto Power Off: 25 minutes
User Maintenance
Regular operator maintenance of the multimeter consists of
cleaning case and window, and battery replacement. All other
repairs must be performed by a factory service center or other
qualified instrument service personnel.
Cleaning Case and window
Periodically wipe the case with a damp cloth and detergent,
allow to dry completely before using; do not use abrasives or
solvents.
Fuse Replacement
1. Disconnect the test leads and turn the meter off. Remove the
test leads from the front terminals.
2. Position the meter face down. Remove the screws from the
case back. Lift the end of the case back until it gently unsnaps.
3. Remove the fuse by gently prying one end of the fuse loose and
sliding the fuse out of the bracket.
4. Verify continuity across the fuse.
5. If the fuse is blown, install a new fuse of the same size and rating.
6. Replace the case top. Reinstall screws.
11/26/07
4:51 PM
Page 13
Battery Replacement
When the multimeter displays the
replaced to maintain proper operation.
To prevent electrical shock hazard, turn off the multimeter and discon-
nect test leads before removing the back cover.
1. Disconnect the test leads and turn the meter off. Remove the test
leads from the front terminals.
2. Position the meter face down. Remove the screws from the case
bottom.
3. Lift the end of the case back until it gently unsnaps.
4. Lift the battery from the case back.
5. Replace battery.
6. Replace the case top. Reinstall screws.
Warranty Statement:
This tester is warranted to the original purchaser against defects
in material and workmanship for two years from the date of
purchase. During this warranty period, IDEAL INDUSTRIES, INC.
will, at its option, replace or repair the defective unit, subject to
verification of the defect or malfunction. This warranty does not
cover fuses, batteries or damage from abuse, neglect, accident,
unauthorized repair, alteration, or unreasonable use of the
instrument.
Any implied warranties arising out of the sale of an IDEAL
product, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited
to the above. The manufacturer shall not be liable for loss of
use of the instrument or other incidental or consequential
damages, expenses, or economic loss, or for any claim or
claims for such damage, expenses or economic loss.
State laws vary, so the above limitations or exclusions may not
apply to you. This warranty gives you specific legal rights, and
you may also have other rights which vary from state to state.