PLACING THE MACHINE IN SERVICE
LUBRICATION
Always use of an air line lubricator with these tool. We
recommended the following Filter-Lubricator-Regulator
Unit: FACOM N.582.
Every eight hours' operation, if a lubricator is not used on
the compressed air network, inject 1/2 to 1cm
machine's inlet connection.
Model
Square
NM.3000F
NM.3000LF
Model
Free speed
rpm
NM.3000F
5000
NM.3000LF
5000
* k = measurement uncertainty in dB
WE, FACOM S.A.S., 6/8 RUE GUSTAVE EIFFEL - BP 99 - 91 423 MORANGIS CEDEX FRANCE, DECLARE UNDER
OUR OWN RESPONSIBILITY THAT THE PRODUCTS NM.3000F & NM.3000LF – FACOM 1" AIR IMPACT WRENCH
- IS IN CONFORMITY WITH THE «MACHINERY» DIRECTIVE 2006/42/CE
- AND IS IN CONFORMITY WITH THE PROVISIONS OF THE HARMONISED EUROPEAN STANDARD
EN ISO 11148-6: 2012
EN ISO 12100:2010
EN ISO 15744:2008
EN ISO 28927-2:2009
NU-NM.3000F NM.3000LF_0515.indd 8
through the
3
Optional tool support hangersfor use
with balancers. Not for hoisting tool or
securing.
Impact
Max.
drive
rate
Torque
''
bpm
N.m
1"
900
3390
1"
900
3390
Air
Working
consumption
pressure
l/min
bar
340
6,2
340
6,2
** k = measurement uncertainty in m/s²
CE DECLARATION OF CONFORMITY
EMERGENCY
GATE VALVE
Noise level
Pressure
Power
dB(A)
dB(A)
k*
k*
100,9
3
111,9
3
100,1
3
111,1
3
Weight
Dimensions
kg
mm
6,89
243,8 x 96,5 x 249
7,39
391,2 x 96,5 x 249
Vibrations
level
m/s
2
Pressure
dB(C)
k*
k**
125
3
10,6
1,55
126
3
11,7
1,65
23.01.2015
FACOM QUALITY MANAGER