5
FILL THE TANK & CONNECT POWER
A
Property Damage:
of water from the spout. Such a restriction prevents draining
the expansion chamber and could damage the tank.
B
Property Damage:
is filled with water. Failure to do so may damage heating
element or thermal safety fuse and will void the warranty.
C
Property Damage:
safety fuse. If you suspect the thermal fuse is open,
contact your Authorized Service Center
Never place a restriction on the delivery
Valve
Lever
Do not connect electric power until tank
Do not remove or alter the thermal
I I
First, open the shutoff valve all the
way and see if your connections are
watertight. If there are any leaks
carefully re-tighten all connections.
I I
Press valve lever down for about 20
seconds until water freely runs out of
the spout. Hold valve open at least 60
seconds to let the water run to flush
out the lines.
I I
Water will be cold since tank has not
been plugged in yet.
I I
Check all connections to ensure they
are tight and that there are no leaks,
then plug in instant hot water tank.
I I
Allow 10-15 minutes for water to reach
target temperature. Gurgling or hissing is
normal during the initial heating cycle.
Steam and/or hot water coming from the
spout without pressing down on the handle
is also normal. If steam is still emitted after
setup, thermostat adjustments may be
.
needed (pg. 11).