Protection Features; Status Indicator - Ravpower ELEMENT+ Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 14

Protection Features

This jumper cable is for the RAVPower RP-PB063 Car Jump Starter only.
Function
Uses
Short Circuit
If the cable is short circuited
Protection
Low-voltage
If starting on low voltage
protection
When the car is started but the
Reverse-charging
jumper cable is not disconnected
protection
from the car battery and the car
battery voltage is higher than 12.6V
Reverse-polarity
When incorrect polarity is
protection
connected with the car battery
When being used continuously to
jump start cars and the internal
High-temperature
temperature of the jumper cable
protection
exceeds 90°C / 194°F
Note: If being used for more than 5 continuous times on vehicles with an engine larger than
2.0T, the jumper cable will reach a temperature of above 90°C / 194°F. The Status Indicator
will slowly blink red with no current output from the cable.

Status Indicator

• Connect the red and black clip on the vehicle battery with correct polarities (red with
positive and black with negative) and connect the jumper cable with the starter battery,
wait for the green LED to come on and now you can start your vehicle.
• When the jumper cable is connected to the wrong polarities, the jumper cable will be
protected. The Status Indicator will blink red with no current output, and will automatically
return to normal output when the connection is correct.
• When the voltage of the vehicle battery is higher than 12.6V, the jumper cable will enter
reverse-charging protection mode. The Status Indicator will flash green with no current
output. If this happens, please check the vehicle battery level.
• When the starter battery voltage is lower than 12.9V or the battery level is less than 20%,
the jumper cable enters low-voltage protection mode. The Status Indicator will flash red
with no current output. If this happens, you should check the starter battery level and
maybe recharge the battery pack.
Notes
The Status Indicator will flash red and green.
There will be no current output from the cable.
When the battery voltage is ≤ 12.9V or battery level
less than 20%, the Status Indicator will flash red. There
will be no current output from the cable.
The Status Indicator will flash green. There will be no
current output from the cable.
The Status Indicator will blink red. There will be no
current output from the cable.
• If being used continuously to jump start vehicles, the internal temperature of the jumper
cable may exceed 90°C / 194°F due to the high current output. This could also happen if
you are using the jumper cable to start cars with engine larger than 2.0T for more than 5
times in a row. When temperature is exceeding 90°C / 194°F, the jumper cable enters
high-temperature protection mode. The Status Indicator will blink red with no current
output. You will need to wait for the jumper cable to cool down to 70°C / 158°F before
using it again.
• In normal working mode, the green LED stays on.
Warning
1. When jump starting, please make sure the jumper cable is firmly clamped onto the car
battery leads. Improper clamping may damage the battery and even burn the cable.
2. If the car cannot be jump started, please make sure the cable is firmly clamped. Also check
if the battery leads are rusty or dirty. Clean the battery lead if necessary.
3. If you still cannot start the car after three attempts, please stop using the jump battery
pack and check if the car has other issues leading to a breakdown.
4. Do not interconnect the two clamps on the same jumper cable. This will cause serious
damage to the car.
5. Do not dismantle this battery pack. The warranty does not cover products which have
been dismantled.
6. Do not expose the product to water or other liquids.
7. Do not modify the battery.
8. Keep away from children.
9. Make sure the polarities are correct before using.
10. Keep away from fire and extreme heat.
11. Stop using if the battery pack becomes hot or changes color. This may be caused by
internal leakage.
12. Please recharge the battery pack at least once every 3 months.
13. When used to jump start a car, please wait at least 10 seconds before recharging the
battery pack.
14. Please do not use it to repeatedly jump start your car, wait at least 30 seconds before
another attempt.