Cleaning the Filter (see Figures 1 and 2)
If the water flow has decreased, this may be because the filter is clogged. Clean the filter as follows:
– Shut off the water supply to the faucet.
– Remove the connecting hose (7) from the control box.
– Unscrew the connecting nipple (8) and remove the strainer from the nipple.
– Clean the strainer under running water.
– Reassemble the parts.
Troubleshooting
Symptom
Water flow from the outlet
does not stop, or stops
after 40 seconds
Water flow is low and weak
No water comes out of the faucet
Cause / Solution
– The sensing range is too low
– Check that the photocell is clean
– The solenoid valve is damaged
– Filter is clogged
– Check the water supply to the control box
– The solenoid valve is damaged
– Power failure
– The sensor is covered or damaged
– Check the fuse (17) inside the control box:
6100:
0.1 A
6130:
1 A