WARNING
For safe and proper operation plug unit into a properly
grounded electrical outlet of the correct voltage, size and
plug configuration. If the plug and receptacle do not
match, contact a qualified electrician to determine the
proper voltage and size and install the proper electrical
outlet.
WARNING
Units supplied without electrical plug require field
installation of proper electrical plug. Plug must be proper
for the electrical specifications of the unit and power
supply and be grounded.
WARNING
Some exterior surfaces on the unit will get hot. Use
caution when touching these areas to avoid injury.
WARNING
To prevent any injury, discontinue use if power cord is
frayed or worn.
CAUTION
Unit is not weatherproof. For safe and proper operation
the unit must be located indoors where the ambient air
temperature is a minimum of 21°C (70°F) and a maximum
of 29°C (85°F).
FSHAC CONTROL PANEL
1. Plug unit into an electrical outlet of the correct voltage, size
and plug configuration. See SPECIFICATIONS for details.
2. Turn the Power Switch on the control panel to the ON
position. The Power Switch and the Digital Display will light
up at this time. (See 10 )
3. Set Air temperature by pushing TEMPERATURE button
once to display "tsp." Push button again to display current
temperature setting.
4. Push the UP or DOWN arrow buttons until desired
temperature setting is reached. Digital display will return to
current cabinet temperature in a few seconds.
Temperature Range is as follows:
FSHAC-2
27-79°C
FSHAC-3
27-79°C
FSHAC-2PT
27-93°C
FSHACH CONTROL PANEL
1. Plug unit into an electrical outlet of the correct voltage, size
and plug configuration. See SPECIFICATIONS for details.
2. Turn the Power Switch on the control panel to the ON
position. The Power Switch and the Digital Display will light
up at this time. (See 11 )
NOTE: "LO H2O" message will flash on the Digital Display
when
the
unit
is
and -3 models have the capacity to hold 9 liters (2-1/4 gallons)
and FSHACH-2PT models have the capacity to hold 11 liters
(3 gallons) of water. Hatco recommends using softened or
distilled water.
NOTE: To assure proper operation when using distilled water,
add one teaspoon of salt to the water reservoir during the initial
manual fill only.
NOTE: "LO H2O" message will continue to flash on auto-fill
units until the water reservoir is full.
(80-175°F)
(80-175°F)
(80-200°F)
low
on
water.
FSHACH-2
3. On manual fill units, to fill the reservoir, lift the fill cup cover
up and pull forward. Slowly pour the water into the cup until
the "LO H2O" disappears.
4. Set air temperature by pushing TEMPERATURE button
once to display "tsp." Push button again to display current
temperature setting.
5. Push the UP or DOWN arrow buttons until desired
temperature setting is reached. Digital display will return to
current cabinet temperature in a few seconds.
Temperature Range is as follows:
FSHACH-2
FSHACH-3
FSHACH-2PT
6. Set humidity level by pushing HUMIDITY button once to
display "hsp." Push button again to display current
HUMIDITY setting.
NOTE: Temperature and humidity settings may vary
depending upon product make-up and consistency. The lowest
temperature point inside the cabinet is
temperature of product.
7. Push the UP or DOWN arrow buttons until desired
humidity setting is reached (1=low, 5=high). Digital display
will return to current cabinet temperature in a few seconds.
8. Allow 30 minutes to preheat a full reservoir of water to
desired humidity setting.
NOTE: Manual fill water reservoirs will require refilling every
4-8 hours, depending on the settings. "LO H2O" message will
reappear every time the unit has a low water level.
NOTE: Product failure due to lime or mineral deposits is not
covered under warranty.
11
OPERATION
27-79°C
(80-175°F)
27-79°C
(80-175°F)
27-93°C
(80-200°F)
displayed, not the
Form No. FSHACCEM-0807