step 4
- Set the telescopic guide according to the type and thickness of the door, as
indicated in the diagram.
- Fix the telescopic guide on the inside of the door 1 (P1), leaving 7mm distance
between the door edge and the center of the first hole, and 22mm from the bottom
edge to the center of the holes, using the binding screw # 6 x 1/2 " (Q).
P1
7
20
Set-up of the telescopic guide
Interior Door
22
E= 22 - 29 |
E= 20, 21, 30-34
E= 35 |
For Toledo doors, change the idler
on both guides to use the 11.5mm
diameter one.
For this, it is necessary to remove the
Seagers lock and change the idler.
11.5
8.5
+
|