DELTA DORE DFR TYXAL+ Manual De Instalación página 9

Ocultar thumbs Ver también para DFR TYXAL+:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
2. Location
Recommended locations:
In the home:
- Place a detector in each room, avert using listed places to avoid.
- Place a detector on each floor.
- Place a detector close to sleeping areas
(for example, in the corridor leading to rooms; in the case
of a long corridor > 10m, place 1 detector at each end).
- Place a detector in each bedroom occupied by a smoker.
Kitchen
Dining
room
Lounge
In the room:
15-25
cm
Basic protection
Enhanced protection
Bedroom
Bedroom
Smoker
bedroom
Flat
tached to the ceiling in the middle of the room.
Otherwise, attach it more than 20cm from any
obstacle (partition wall, beam, etc.) and over
60cm from any room corner.
the wall at a distance of between 15 and 25cm
from the ceiling.
20 cm
detector at a location between 20 and 90 cm
vertically below the highest point.
90 cm
Bedroom
Lounge
Basement
- 9 -
Corridor
Bedroom
Kitchen
House
-
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido