Description
CAUTION
Do not operate this valve with an antifreeze and water
mixture.
The control valve models included in the 3570 series are
designed to dispense a variety of fluids. These include engine
oils, diesel oils, and hydraulic oils.
WARNING
Release all pressure within the system prior to
performing any overhaul procedure.
• Disconnect the air supply line from the pump
motor.
• Into an appropriate container, operate the control
valve to discharge remaining pressure within the
system.
Never point a control valve at any portion of your body
or another person. Accidental discharge of pressure
and/or material can result in personal injury.
Read each step of the instructions carefully. Make sure
a proper understanding is achieved before proceeding.
Assembly
Apply thread Sealant to the male threads on the extension (1
or 2).
NOTE: Do not apply thread sealant to the first two
(2) threads. Contamination can occur.
Install the Extension into the Handle. Tighten securely.
Prime and Test
NOTE: Perform the following procedures at an air
pressure that allows the pump to begin to cycle.
Regulate the amount of air to the pump with a pres-
sure regulator.
Should valve leakage occur at anytime, refer to the
Troubleshooting Chart.
Model
3570-A
3571-A
This document contains confidential information that is the property of Alemite, LLC
670960
and is not to be copied, used, or disclosed to others without express written permission.
1-800-548-1191 - http://www.partdeal.com - info@partdeal.com
Service Guide
High Volume Control Valve
Fluid
Oil
Oil
Alemite, LLC
167 Roweland Drive, Johnson City, Tennessee 37601
www.alemite.com
©
Copyright
2008 by Alemite, LLC
Figure 1 High Volume Control Valve Model 3570-A & 3571-A
Fluid Inlet (Swivel)
Maximum Operating Pressure
1. Point the control valve into an appropriate collection
container.
2. Allow the pump to deliver fluid to the control valve.
• The control valve should show no leakage nor dispense the
fluid.
3. Cycle the control valve Lever Assembly several times.
• Fluid should flow once air is eliminated from the control
valve (and system).
With the Lever in the released position, no fluid should
appear at the Nozzle. If product does appear, refer to the
Troubleshooting Chart.
The non-drip nozzle opens automatically when fluid is
dispensed.
After use, the nozzle should be manually pushed closed to
prevent oil drip.
Extension
Nozzle Type
Rigid
Non-Drip Manual
Flexible
Non-Drip Manual
3570-A
3571-A
3/4" NPTF (f)
1000 psi (70 bar)
SER 3570-A
Revision (7-08)

Publicidad

loading

Resumen de contenidos para Alemite 3570-A

  • Página 1 © Copyright 2008 by Alemite, LLC SER 3570-A This document contains confidential information that is the property of Alemite, LLC Revision (7-08) 670960 and is not to be copied, used, or disclosed to others without express written permission. 1-800-548-1191 - http://www.partdeal.com - info@partdeal.com...
  • Página 2 SER 3570-A High Volume Control Valve Figure 2 High Volume Control Valve Model 3570 Series - Exploded View Control Valve Model Item Part No. Description Notes 393792-1 Extension, Rigid 393792-2 Extension, Flexible 393792-3 Swivel Assembly 393792-4 Valve Seal Kit Revision (7-08) Alemite, LLC 1-800-548-1191 - http://www.partdeal.com - info@partdeal.com...
  • Página 3: Troubleshooting Chart

    High Volume Control Valve SER 3570-A Troubleshooting Chart Control Valve Indications Possible Problems Solutions Continuous product flow 1. Foreign material on Valve Seal 1. Disassemble, clean, and inspect seat area. Check mating surfaces and replace Seals as necessary. Locate and eliminate source of foreign material.
  • Página 4: Guía De Servicio

    Manual Anti-Goteo © Copyright 2008 by Alemite, LLC Este documento contiene información confidencial que es propiedad de Alemite, LLC SER 3570-A y no se debe copiar, usar o revelar a terceros sin una expresa autorización por escrito. Revisión (9-08) 670960...
  • Página 5 Control de Alto Volumen SER 3570-A á Figure 2 Válvula de Control de Alto Volumen - Vista esquemática Modelo de válvula Nº de de control Nº de ítem Descripción Cant Notas parte 393792-1 Extensión Rígida 393792-2 Extensión Flexible...
  • Página 6 Control de Alto Volumen á SER 3570-A Tabla de localización de fallas Indicaciones de la válvula continua Posibles problemas Soluciones 1. Existe material extraño en el sello (2d) 1. Desmonte, limpie e inspeccione el área El flujo de fluido es continuo del sello.

Este manual también es adecuado para:

3571-a