Ventilation Fan
with Light
MODEL: 8663RP, 8664RP
Suitable for use in shower or tub enclosure when used
with GFI protected branch circuit.
Suitable for use in insulated ceilings.
WARNING: To reduce the risk of fire or electrical shock, do not use this
fan with any solid-state speed control device. Do not install in a ceiling
insulated to a value greater than R-40.
IMPORTANT SAFETY INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at Service Panel and
lock Service Panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fas-
ten a prominent warning device, such as a tag, to the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
INSTALLATION INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s)
in accordance with all applicable codes and standards, including fire-rated
construction.
B. Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA),
and the American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application.
F. NEVER place a switch where it can be reached from a tub or shower.
G. For installation in sloped ceilings up to 12/12 pitch.
H. Ductwork must point up.
FOR BEST RESULTS
When installing the Exhaust Fan/Light in a new construction site, install
housing during the rough-in construction of the building. The blower unit,
reflector and grille should be installed after the finished ceiling is in place.
Refer to instructions on page 3 to install the Exhaust Fan/Light in an exist-
ing finished building.
PLANNING DUCTWORK AND WIRING
1. Use 4" round duct.
2. Plan duct run from discharge opening of fan to the outside. For best fan
performance, make duct run as short as possible and use minimum num-
ber of elbows.
3. Use optional NuTone ducting accessories as needed.
TO REGISTER THIS PRODUCT, VISIT WWW.NUTONE.COM
READ & SAVE THESE INSTRUCTIONS!
Hanger Bars
Slots
Tabs
Night Light
Socket
(not provided
on 8664RP)
IMPORTANT: Use wire suitable for 90°C.
Plan to run 120vAC house wiring (with ground) from power source, through
wall switches, to junction box in fan. For separate control of fan, light, and
night light three wall switches are required. See NuTone Catalog for accesso-
ry switches. For separate control of fan, light, and night light, five conductors
are needed between the wall switch box and the fan's junction box. (Night
light not provided on 8664RP).
INSTALLATION IN A NEW
CONSTRUCTION SITE
PREPARATION
1. Refer to Figure 1. Remove power unit/blower assembly from housing.
A. Unplug power unit.
B. Remove screw (located next to plug-in receptacle) which holds power/
blower unit mounting plate in place. Save screw.
C. Lift mounting plate at end near the plug-in receptacle until blower
wheel clears the scroll.
D. Remove plate by pulling its tabs out of slots in housing. Set power/
blower unit aside until needed.
2. Remove one of the wiring knockouts from housing.
INSTALLATION INSTRUCTIONS
Wiring
Knockouts
Housing
Scroll
Power/Blower
Unit
Reflector
Assembly
Acorn Nut
Mounting
Springs (2)
Grille/Lens
Assembly
Duct
Collar
FIGURE 1

Publicidad

loading

Resumen de contenidos para NuTone 8663RP

  • Página 1 For separate control of fan, light, and C. When cutting or drilling into wall or ceiling, do not damage electrical wiring night light three wall switches are required. See NuTone Catalog for accesso- and other hidden utilities.
  • Página 2 2. Insert and secure an approved box connector into wiring entrance hole. 3. Pull wires through box connector and into junction box. Tighten box connector. 4. Refer to Figure 4A. (For 8663RP) Connect white wires from the fan and light receptacles to white (neutral) wire...
  • Página 3: Completing Installation

    POWER/BLOWER UNIT INSTALLATION 11-1/2” 1. Refer to Figure 1. Place power/blower unit into housing so that mounting plate’s tabs insert into slots in housing. 2. Press other end of mounting plate down until it is firmly seated over scroll 5-3/4” and plug-in receptacles.
  • Página 4 Pour une D. Les ventilateurs avec gaine doivent toujours avoir une une évacuation extéri- commande séparée du ventilateur et de l’éclairage, utiliser un interrupteur NuTone eure. en option (la veilleuse n’accompagne pas le modèle 8664RP).
  • Página 5 LAMPE VELLEUSE 4. Voir Figure 4A. (pour le modèle 8663RP) Relier les câbles blancs des prises du ventilateur et d’éclairage au câble blanc d’alimentation générale (neutre.) Relier le câble noir au câble provenant de l’interrupteur du ventilateur. Relier le câble rouge au câble provenant de l’interrupteur de la lampe.
  • Página 6 INSTALLATION DU BLOC-MOTEUR 11-1/2” 1. Voir Figure 1. Placer le bloc-moteur dans le boîtier de sorte que les pattes de la plaque de montage s’insèrent dans les fentes du boîtier. 2. Appuyer sur l’autre extrémité de la plaque de montage pour la faire descen- 5-3/4”...
  • Página 7 C. Cuando corte o taladre en la pared o el techo, no dañe el cableado eléctrico ni otros servicios escondidos. se necesitan tres interruptores de pared. Consutle el Catálogo NuTone para ver los D. Los ventiladores entubados siempre deben estar ventilados hacia el exterior.
  • Página 8 3. Tire de los cables a través del conectador de caja y dentro de la caja de empalme. Aprete el conectador de caja. 4. Consulte la Figura 4A. (para modelo 8663RP) Conecte los cables blancos de los receptáculos del ventilador y de la luz la cable blanco (neutro) de la alimentación.
  • Página 9 5. Conecte el cable verde (desnudo) de conexión a tierra al hilo verde de conexión a tierra. 11-1/2” INSTALACION DE LA UNIDAD DE POTENCIA/SOPLADOR 5-3/4” 1. Refiérase a la Figura 1. Coloque la unidad de potencia/soplador en la caja para que las lengüetas de la placa de montaje se inserten en las ranuras de la caja.
  • Página 10 MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.
  • Página 11: Service Parts

    SERVICE PARTS ModelS 8663RP & 8664RP KEY NO. PART NUMBER DESCRIPTION 97017705 Power Unit Assembly (8663RP) 97017706 Power Unit Assembly (8664RP) 100599000 Motor 32787000 Motor Isolation Mount 32788000 Ground Clip 100603000 Blower Wheel 85974000 Reflector Assembly (8663RP) 86000000 Reflector Assembly (8664RP)