SPECTRE Module Industry - SMI
Frequency Band: 865 - 868 MHz
Frequency Band: 902 - 928 MHz
SMI/SLI:
To supply model or to provide V+, V- use only power adaptors with outputs in compliance with ES1 and PS2 (LPS per Annex Q of IEC/UL/EN 62368-
1) types.
V+, V- musn't exceed 30 Vdc.
Main power supply:
Range +12 Vdc up to +30 Vdc
Consumption:
Typical: 0.6 A under +24 Vdc
SMI/SLI-POE+:
Use an IEEE 802.3at.2009-compatible PSE (Power Sourcing Equipment).
Main power supply:
Range +42.5 Vdc to +57 Vdc
If several readers are connected to the PSE, check that each port of the PSE supplies 20W.
Communication:
RS485 (L+ & L-) / RS232 (TD & RD) (SUB D9) / Ethernet (RJ45) / USB C (wedge mode)
Temperature:
-25°C to +60°C / -13°F to +140°F
Protection:
IP53 level
Chip:
EPC1 Gen2 (ISO 18000-63) - 1 to 62 bytes max
I/O:
4 optocoupled inputs and 4 optocoupled outputs
Module LED:
1 red LED: presence of power supply
Antenna LED:
7 colors (red, green, blue, orange, purple, turquoise, white) controlled by SSCP commands
Use a multi-conductor shielded twisted pair cable
Max length RS485:
3 280 ft / 1000 m at 9600 baud (SYT2 AWG24 recommended)
Max length RS232:
49.21 ft / 15 m (SYT2 AWG24 recommended)
Ethernet:
100m, category 5E
▪ Install the module/reader away from computer transmission cables or from power sources (ex: RJ45, sector...).
The disruptions that they can cause can vary according to their radiation power and their proximity.
▪ Use a filtered and regulated power supply.
▪ Antennas connected to different modules/readers may interfere with each other. Move them away from each other.
▪ A power supply which provides 1 A min under +24Vdc is recommended.If the IN/OUT are powered by the module, use a 2A min under +24Vdc power supply.
▪ Users must not remain within a range of less than, 34 cm / 13.39 in from an antenna for an extended period of time as per EN50364 applicable to this
type of device.
▪ Apart from the hatch the module housings must not be opened.
▪ Before any service operation you must de-energize reader.
▪ Check that the hatch seal is correctly positioned before closing.
Power jack
Power plug S761K
SPECTRE UHF INDUSTRY
Installation procedure
SMI-W42-A-U04: RS232
SMI-W43-A-U04: RS485
SMI-W44-A-U04: TCP-IP + POE
SMI-W52-A-U04: RS232
SMI-W53-A-U04: RS485
SMI-W54-A-U04: TCP-IP+ POE
Power Supply Characteristics - SMI /SLI
Typical: +24 Vdc
Max: 0.8 A under +24 Vdc
Typical: +48 Vdc
Recommended Cables - SMI / SLI
Front View of the Module - SMI / SLI
RJ45
DE9
RS232/ RS485 / IN/OUT CONNECTION - SMI / SLI
DE9
Female/SMI
Male/Host
© STid - 20 PA des Pradeaux FR13850 Gréasque – NI1141X01 - Page 1 sur 12 - Ed. 24/07/2020
UHF SPECTRE INDUSTRY
Notice d'installation
Frequency Band: 865 - 868 MHz
ERP: 2W
+
Frequency Band: 902 - 928 MHz
EIRP: 4W
+
Characteristics - SMI / SLI
Recommendations - SMI / SLI
Red LED
M12
USB C
RF port 1
RS232
RS485
1
NC
NC
NC
2
Tx_SMI/Rx_Host
NC
3
Rx_SMI/Tx_Host
NC
NC
4
5
GND
GND
6
NC
L- / B
NC
NC
7
NC
8
L+/ A
NC
NC
9
UHF SPECTRE INDUSTRY
Manual de instalación
SPECTRE Reader Industry - SLI
SLI-W42-A-U04: RS232
SLI-W43-A-U04: RS485
SLI-W44-A-U04: TCP-IP + POE
SLI-W52-A-U04: RS232
SLI-W53-A-U04: RS485
SLI-W54-A-U04: TCP-IP + POE
RF port 2
RF port 4
RF port 3
M12 A-coded: IN/OUT
1
Female
2
3
4
5
6
7
8
Male
9
10
11
12
US
FR
ES
+
+
+Vcc
OUT1
IN3
V- OPTO
IN1
GND
V+ OPTO
OUT4
OUT3
OUT2
IN2
IN4