Electrical
Hazardous voltage. Can shock, burn, or kill.
Connect ground wire before connecting power supply
wires. Use the wire size (including the ground wire) spec-
ified in the wiring chart. If possible, connect the pump to
a separate branch circuit with no other appliances on it.
Explosion hazard. Do not ground to a gas
supply line.

WIRING CONNECTIONS

Fire hazard. Incorrect voltage can cause a
fire or seriously damage the motor and voids the warranty.
The supply voltage must be within ±10% of the motor
nameplate voltage.
NOTICE: Dual-voltage motors are factory wired for 230
volts. If necessary, reconnect the motor for 115 volts, as
shown. Do not alter the wiring in single voltage motors.
Install, ground, wire, and maintain your pump in compli-
ance with the National Electrical Code (NEC) or the
Canadian Electrical Code (CEC), as applicable, and with
all local codes and ordinances that apply. Consult your
local building inspector for code information.
Motor
Series
PN
PN
PN
FSNCH
FSNDH
Wiring Chart – Recommended Wire and Fuse Sizes
Max.
Load
HP
Volts
Amp
1/3
115
9.4
1/2
115
9.4
3/4
115/230
12.2/6.1
1/2
115/230
8.8/4.4
3/4
115/230
12.4/6.2

Connection Procedure:

1. Connect the ground wire first as shown in Figure 7. The
ground wire must be a solid copper wire at least as
large as the power supply wires.
2. There must be a solid metal connection between the
pressure switch and the motor for motor grounding pro-
tection. If the pressure switch is not connected to the
motor, connect the green ground screw in the switch to
the green ground screw under the motor end cover. Use
a solid copper wire at least as large as the power sup-
ply wires.
3. Connect the ground wire to a grounded lead in a ser-
vice panel, to a metal underground water pipe, to a
metal well casing at least ten feet (3M) long, or to a
ground electrode provided by the power company or
the hydro authority.
4. Connect the power supply wires to the pressure switch
as shown in Figure 9, Page 7.
DISTANCE IN FEET(METERS) FROM MOTOR TO SUPPLY
Branch
0 - 100
101 - 200
Fuse
(0 - 30)
(31 - 61)
Rating
Amp
15
14(2)
10(5.5)
15
14(2)
10(5.5)
20/15
12/14(3/2) 10/14(5.5/2) 8/14(8.4/2)
15/15
14/14(2/2)
12/14(3/2)
20/15
12/14(3/2) 10/14(5.5/2) 8/14(8.4/2)
201 - 300
301 - 400
(62 - 91)
(92 - 122)
AWG WIRE SIZE (mm
)
2
10(5.5)
6(14)
10(5.5)
6(14)
6/12(14/3)
10/14(5.5/2) 8/14(8.4/2)
6/12(14/3)
8
401 - 500
(123 - 152)
6(14)
6(14)
6/12(14/3)
8/12(8.4/3)
6/12(14/3)