Irritrol Rain Dial Plus 6 Guia Del Usuario página 15

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Automatic Operation, Step by Step continued...
Press the Next
Button to select the current DAY (1–15) of the Skip Days
schedule. This determines when the watering interval will begin. At the day change
(midnight), the DAY number automatically increases by one. When the SKIP and
DAY numbers are equal, watering will occur at the first scheduled start time.
Note: If an Odd/Evn schedule is in use, it must be set to "OFF" before a Skip Days
schedule can be set. (See page 19, "What the Display Means.")
Odd/Even Days Schedule
Turn the Dial to ODD/EVEN. Press the +/- Buttons to select ODD, EVN or OFF.
Note: Odd/Evn schedule overrides the Skip Days or Daily schedules and must be set
to "OFF" to use another type of schedule.
Note: ODD days will not water on the 31st of a month or Feb. 29 during leap year.
4. Turn the Dial to Start Times
Turn the Dial to Start Time 1. Press the +/- Buttons to the time you want this
Program to start.
Note: OFF settings are located between 11:59 a.m./12:00 p.m., and
11:59 p.m./12:00 a.m.
If desired, add second and third Start Times to this PROGRAM by changing the Dial
position to 2 or 3 and repeating the above procedure.
5. Turn the Dial to Valve Run Times
Turn the Dial to the number of the valve you want to operate. Press the +/- Buttons
to set the number of minutes to water. The values larger than one hour show as
hours and tenths of hours, for example, 1.1 hour means 1 hour and 6 minutes.
Repeat for each valve you want to operate within the selected Program.
To set another PROGRAM, repeat steps 2 through 5.
Your program is now complete and ready to run.
Set the Function Switch to Run
clock reaches the next start time.
.
.
and your system will run when the

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rain dial plus 9Rain dial plus 12

Tabla de contenido