Descargar Imprimir esta página

GES LUTRON C.L Guia De Inicio Rapido página 2

Publicidad

C L
Dimmer
Ariadni
Important Notes:
Please read before installing.
1. CAUTION: Use only with permanently installed xtures with dimmable screw-in compact
uorescent, dimmable screw-in LED, halogen, or incandescent lamps. To avoid overheating
and possible damage to other equipment, do not use to control receptacles, motor-driven
appliances, or transformer-supplied appliances.
2. Install in accordance with all national and local electrical codes.
3. Only one Dimmer can be used in a 3-way circuit.
4. When no "grounding means" exists within the wallbox for an existing switch or dimmer,
the 2011 National Electrical CodeR (NECR) allows a switch/dimmer to be installed as a
replacement as long as 1) a nonmetallic, noncombustible faceplate is used with nonmetallic
attachment screws or 2) the circuit is protected by a ground fault circuit interrupter. The
2008 NECR has the same allowances but does not contain the requirement for nonmetallic
attachment screws.
5. For new installations, install a test switch before installing the Dimmer.
6. Protect Dimmer from dust and dirt when painting or spackling wall.
7. It is normal for the Dimmer to feel warm to the touch during operation.
8. Clean dimmer with a soft damp cloth only. Do not use any chemical cleaners.
9. For indoor use only.
10. Controls must be mounted vertically. See stamp on control for correct positioning.
See written Instructions at right
Ver instrucciones detalladas a la derecha
Voir les directions écrites à la droite
1
6
Helpful Hint: If you are replacing a single-pole switch, the screw
on the same side as the different-colored screw is not used.
Nota: Si esta reemplazando un interruptor unipolar el tornillo en
el mismo lado del tornillo de color diferente no se usa.
WARNING
Shock Hazard. May result in serious injury or
Conseil utile : si vous remplacez un interrupteur unipolaire la vis
death. Turn OFF power at circuit breaker
(or remove fuse) before installing the unit.
située sur le même côté que la vis de couleur différente ne sera
pas utilisée.
Peligro de choque eléctrico. Podría resultar
ADVERTENCIA
en lesiones graves o la muerte. Desconnecte
la alimentación en el disjuntor (o retire
el fusible) antes del instalorla unidad.
A
Danger d'électrocution. Peut causer le décès
AVERTISSEMENT
de la personne ou de graves lésions. Couper
le courant au disjoncteur (ou retirer le
fusible) avant de proceder à l'installation.
2
3
A
B
1
1
Live |
Vivo |
Vivant
Ground | Tierra |
Ground | Tierra |
120 V~
Mise à la terre
Mise à la terre
60 Hz
Neutral | Neutro |
Different-colored screw |
Neutre
Tornillo de diferente color | Vis de couleur différente
4
7
Continuous Wire | Alambre continuo |
2 Wires | 2 alambres | 2 ls
Fil continu
8
Tape Before Disconnecting | Unir con cinta antes de desconectar | Appliquer un ruban
avant la déconnexion
5
Prepare Wires: Trim or strip wallbox wires to the length indicated by the strip gauge on the back
of the dimmer. Use the same procedure to wire your new dimmer as was used with the old switch.
Prepare alambres: Torce y corte todos los alambres a la longitud indicada al reverso del
atenuador. Use el mismo procedimiento de la conexión del interruptor para conectar el atenuador.
Préparer les fils : Couper ou dénuder les fils de la boîte de sortie conformément aux longueurs
indiquées à l'arrière du gradateur. Pour con nect er votre nouveau gradateur, utiliser la même
procédure que celle utilisée pour l'ancien interrupteur (voir la 3
e
étape 3 et ci-dessous).
U.S.A., Canada and
the Caribbean
1.800.523.9466
México
+1.888.235.2910
For more information | Para más información | Pour plus d'information
, Toggler
Lutron Electronics Co., Inc. | 7200 Suter Road | Coopersburg, PA 18036-1299, U.S.A.
®
®
Notas importantes:
Por favor lea antes de realizar la instalación.
1. PRECAUCIÓN: Utilizar únicamente con luminarias de instalación ja y con los siguientes
focos roscados y atenuables: lámpara uorescente compacta autobalastrada, LED y
halógenos o incandescentes. Para evitar recalentamientos y posibles daños a otros equipos,
no lo utilice para controlar receptáculos ni electrodomésticos a motor o con transformador.
2. Realice la instalación de acuerdo con todos los códigos eléctricos nacionales y locales.
3. En un circuito de 3 vías puede utilizarse sólo un atenuador.
4. Cuando no hay "medios de conexión a tierra" dentro de la caja de pared para un interruptor
o atenuador existentes, el 2011 National Electrical CodeR (NECR Código eléctrico nacional)
permite la instalación de un atenuador como reemplazo en tanto 1) se utilice una carátula no
combustible con tornillos de anexión no metálicos o 2) el circuito se proteja a través de un
interruptor de circuitos de falla de tierra. El NECR de 2008 proporciona los mismos permisos,
aunque no incluye el requisito de tornillos de anexión no metálicos.
5. Para las instalaciones nuevas, instale un interruptor de prueba antes de instalar el atenuador.
6. Proteja el atenuador contra el polvo y la suciedad al pintar o reparar las paredes.
7. Es normal que el atenuador se sienta tibio al tacto durante su funcionamiento.
8. Limpie el atenuador con un paño suave y húmedo solamente.
No use productos químicos de limpieza.
9. Sólo para uso en interiores.
10. Los controles deben montarse verticalmente. El grabado del control muestra la posición
correcta.
English
C L
Dimmer
120 V
60 Hz
See Multigang Section for Maximum Load Ratings
Models:
Please reference corresponding illustrations
at left
1
2
Remove wallplate and switch mounting screws.
B
2
2
Leaving all wires attached, carefully remove switch from wall.
Identify switch type.
3
Ground | Tierra |
Ground | Tierra |
Mise à la terre
Mise à la terre
Single pole- The switch will have insulated wires connected to two
screws of the same color plus a green ground screw. (See Single Pole
Diagrams
3-way- 3-way switches will have insulated wires connected to three
screws plus a green ground screw. One of these wires is connected to a
screw of a different color (not green) or labeled COMMON. Tag this wire
to identify when removing. (See 3-Way Diagrams
4
Disconnect the wires from the switch. Your wall switch may have two
wires attached to the same screw. Tape these two wires together
Dimmer |
Dimmer |
Atenuador |
before disconnecting.
Atenuador |
Gradateur
Gradateur
For installations involving more than one control in a wallbox.
See Multigang and Mixed Bulb Type (on other side)
Ground | Tierra |
Mise a la terre
Ground | Tierra |
Prepare wires:
5
Mise a la terre
Push-In Terminals: Insert wires fully. Note: Backwire holes are for
use with 14 AWG (1.5 mm
wire, consult an electrician. DO NOT use stranded or twisted wire. Or,
Live |
Screw Terminals: Tighten securely. Screw terminals are for use with
Vivo |
3-way Switch |
solid copper wire only. For aluminum wire, consult an electrician. DO
Vivant
3-vías interruptor |
NOT use stranded or twisted wire.
Interrupteur de
120 V~
3-voies
6
6A: Replacing a single pole switch
60 Hz
Switch will be replaced with a Dimmer.
Light |
Light |
Làmpara |
Làmpara |
Neutral | Neutro |
Lampe
Lampe
See Diagram
Neutre
A
2
at left
c. Connect the remaining wire removed from the switch to the screw (or
6B: Replacing a 3-way switch
When installing a Dimmer in a Multi Location situation, lights can be
dimmed from 1 location and switched on/off from all other locations.
See Diagram
B
2
at left
c. Connect one of the remaining wires removed from the switch to
d. Connect the last wire removed from the switch to the remaining
7
Form wires carefully into wallbox and mount Dimmer, but do not install
faceplate yet.
8
Turn Power ON at circuit breaker (or replace fuse).
9
Limited Warranty
(Valid only in the U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture
within one year after purchase. For warranty service, return unit to place of purchase or
mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
This warranty is in lieu of all other express warranties, and the implied warranty
of merchantability is limited to one year from purchase. This warranty does not
cover the cost of installation, removal or reinstallation, or damage resulting from
misuse, abuse, or damage from improper wiring or installation. This warranty
does not cover incidental or consequential damages. LUTRON'S LIABILITY ON ANY
Others | Otros | D'autres
CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE,
SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE
+1.610.282.3800
PURCHASE PRICE OF THE UNIT.
This warranty gives you speci c legal rights, and you may have other rights which vary
Fax | Télécopieur
from state to state. Some states do not allow the exclusion or limitation of incidental or
consequential damages, or limitation on how long an implied warranty may last, so the
+1.610.282.6311
above limitations may not apply to you.
Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association,
www.lutron.com
Quincy, Massachusetts. © 2011 Lutron Electronics Co., Inc.
24/7 Help | Aide 1.800.523.9466
Remarques importantes :
Veuillez lire les directives avant l'installation.
1. MISE EN GARDE : Utilisez seulement avec des appareils d'éclairage installés en permanence
avec des ampoules à incandescence ou halogènes ou à DEL à intensité réglable, vissées,
compactes, uorescentes. Pour éviter la surchauffe et ne pas endommager d'autres appareils,
ne pas utiliser pour contrôler une prise de courant murale ou un appareil motorisé ou alimenté
par transformateur.
2. Effectuez l'installation conformément à tous les codes d'électricité locaux et nationaux.
3. Un seul gradateur peut être utilisé dans un circuit à 3-voies.
4. Si aucun dispositif de mise à la terre n'existe dans le boîtier mural d'un interrupteur ou
gradateur existant, le 2011 National Electrical CodeR (NECR, code électrique national) autorise
l'installation d'un gradateur en guise de remplacement à condition 1) qu'une têtière non-
métallique et non-combustible soit utilisée avec des vis de xation non-métalliques, ou 2) que
le circuit soit protégé par un disjoncteur de fuite de terre. Le code NECR 2008 comprend les
mêmes directives à l'exception de l'exigence concernant les vis de xation non-métalliques.
5. Pour de nouvelles installations, faites un essai avec un commutateur ordinaire avant
d'installer le gradateur.
6. Lors de la peinture des pièces ou de nition de plâtre, protégez toujours le gradateur contre
la poussière et les saletés.
7. Il est normal que le gradateur soit chaud au toucher durant le fonctionnement.
8. Nettoyez le gradateur à l'aide d'un chiffon doux humide seulement. N'employez aucun
nettoyant chimique.
9. Pour installation à l'intérieur seulement.
10. Montez les contrôles à la verticale. Pour un positionnement exact, voir l'estampage sur le contrôle.
Español
Atenuador
C L
LED
600 W
OR
150 W
120 V
Incandescent /
Compact Fluorescent (CFL) /
60 Hz
Halogen
LED
Consulte la sección de múltiples dispositivos
para ver las especi caciones de carga máxima
AYCL-153P (Ariadni) | TGCL-153P (Toggler)
Modelos:
1
WARNING
Shock Hazard. May result in serious injury or
death. Turn OFF power at circuit breaker
(or remove fuse) before installing the unit.
2
3
A
&
A
)
1
2
B
&
B
)
1
2
4
5
) solid copper wire only. For aluminum
2
6
a. Connect the bare copper or green ground wire to the green
ground screw on the dimmer (see Important Note 4).
Ver diagrama
b. Connect one of the remaining wires removed from the
A
switch to the different-colored screw (or backwire hole) on
the dimmer.
a la izquierda
backwire hole) opposite the different-colored screw on the dimmer.
a. Connect the bare copper or green ground wire to the
green ground screw on the dimmer (see Important Note 4).
b. Connect the tagged wire removed from the switch to the
different-colored (COMMON) screw (or backwire hole) on the
Ver diagrama
dimmer. If two wires were taped together, connect one wire to
B
the screw and insert the other wire into the backwire hole near
the screw.
a la izquierda
either of the remaining screws (or backwire holes) on the dimmer.
screw (or backwire hole) on the dimmer.
7
IMPORTANT
See reverse for information on how to adjust this
8
dimmer to your particular bulbs.
9
Garantía limitada
(Válida solamente en E.U.A., Canadá, Puerto Rico y el Caribe.)
Lutron reparará o reemplazará, a su criterio, cualquier unidad que presente fallas en
sus materiales o fabricación dentro del año posterior a su compra. Para obtener el servicio
de garantía, devuelva la unidad al lugar donde la adquirió o envíela a Lutron, 7200 Suter Rd.,
Coopersburg, PA 18036-1299, con servicio postal prepago.
Esta garantía reemplaza a toda otra garantía expresa; la garantía implícita de
comerciabilidad está limitada a un año desde la fecha de compra. Esta garantía
no cubre el costo de instalación, de remoción ni de reinstalación, ni daños
causados por uso incorrecto o abuso, ni daños resultantes de un cableado o una
instalación incorrectos. Esta garantía no cubre daños incidentales ni indirectos.
LA RESPONSABILIDAD DE LUTRON ANTE UNA DEMANDA POR DAÑOS DEBIDOS A LA
FABRICACIÓN, VENTA, INSTALACIÓN, ENTREGA O USO DE LA UNIDAD, O RELACIONADOS CON
ESTOS PROCESOS, NO EXCEDERÁ EN NINGÚN CASO EL PRECIO DE COMPRA DE LA UNIDAD.
La presente garantía le otorga derechos legales especí cos, pero podría tener también otros
derechos que varían según el estado. Algunos estados no permiten la exclusión o limitación
de los daños incidentales o indirectos, ni limitaciones en la duración de las garantías implícitas,
de modo que dichas limitaciones pueden no ser aplicables en su caso.
Electronics Co., Inc. NEC es una marca registrada de National Fire Protection Association,
Quincy, Massachusetts.
© 2011 Lutron Electronics Co., Inc.
U.S.A., Canada and the Caribbean
Français
Gradateur
C L
CFL/LFCA
LED
600 W
O
150 W
120 V
Incandescente/
Lámpara fluorescente compacta
60Hz
halógeno
autobalastrada (LFCA) / LED
Pour connaître la charge maximale d'application,
voir la section jumelage multiple
Modèles :
AYCL-153P (Ariadni) | TGCL-153P (Toggler)
Por favor consulte los ejemplos ilustrados
a la izquierda
1
Peligro de choque eléctrico. Podría resultar
ADVERTENCIA
en lesiones graves o la muerte. Desconnecte
la alimentación en el disjuntor (o retire
el fusible) antes del instalorla unidad.
2
Retire los tornillos de montaje de la tapa y del interruptor. Retire
cuidadosamente el interruptor de la pared sin desconectar ningún cable.
3
Identi que el tipo de interruptor. Unipolar: El interruptor tendrá cables
aislados conectados a dos tornillos del mismo color, más un tornillo
de tierra, de color verde. (Consulte los diagramas unipolar
A
y
A
)
1
2
3 vías: Los interruptores de 3 vías tendrán cables aislados conectados a
tres tornillos, más un tornillo de tierra, de color verde. Uno de estos
cables estará conectado a un tornillo de color distinto al verde o etiquetado
como "COMÚN". Rotule este cable para poder distinguirlo cuando
lo retire. (Consulte los diagramas 3 vías
B
y
B
)
1
2
4
Desconecte los cables del interruptor. Su interruptor de pared podría
tener dos cables conectados al mismo tornillo. Una ambos cables con
cinta adhesiva antes de desconectarlos.
Para instalaciones con más de un control en una misma caja de empotrar.
Consulte la sección de potencia máxima permitida en instalaciones
con múltiples dispositivos y con focos combinados (en el reverso).
5
Prepare alambres:
Agujeros para conexión posterior: Introduzca el alambre completamente
en el agujero. Nota: Agujeros para conexión posterior son para usar con
(14 AWG) alambre de cobre sólido solamente. Para
un número 1,5 mm
2
alambres de aluminio, consulte un electricista. NO USE alambres normal
o trenzado. O Terminales de tornillos: Asegure terminales. Agujeros
para terminales de tornillos son para usar con alambre de cobre sólido
solamente. Para alambres de aluminio, consulte un electricista.
6
6A: Reemplazo de un interruptor unipolar
El interruptor será reemplazado por un atenuador.
diagramme
a. Conecte el cable de tierra de color verde del atenuador al cable
de cobre sin aislamiento o al cable de tierra verde de la caja de
2
empotrar (Consulte la nota 4 de la sección de Notas importantes).
b. Conecte uno de los alambres removidos del interruptor al
sur la gauche
tornillo de color diferente (o agujero para conexión posterior)
en el atenuador.
c. Conecte el alambre restante removido del interruptor al tornillo (o
agujero para conexión posterior) que está opuesto al tornillo de color
diferente en el atenuador.
6B: Reemplazo de un interruptor de 3 vías
Cuando se instala un atenuador en un entorno de control desde
ubicaciones múltiples, las luces pueden atenuarse desde 1 ubicación
y encenderse o apagarse desde las demás.
diagramme
a. Conecte el alambre verde o de tierra cobre y desnudo al tornillo
verde de tierra en el atenuador (vea Nota Importante 4).
2
b. Conecte el alambre etiquetado removido del interruptor al
sur la gauche
tornillo de color diferente rotulado «COMMON» (o agujero para
conexión posterior) en el atenuador. Si dos alambres fueron
unidos con cinta puede conectar uno al tornillo y el otro al
agujero para conexión posterior próximo al tornillo.
c. Conecte uno de los alambres restantes removidos del interruptor a uno de
los tornillos restantes (o agujeros para conexión posterior) en el atenuador.
d. Conecte el último alambre removido del interruptor al tornillo restante
7
(o agujero para conexión posterior) en el atenuador.
Inserte los cables cuidadosamente en la caja de empotrar y monte
8
el atenuador sin instalar la tapa todavía.
Conecte la alimentación en el cortacircuitos (o reemplace el fusible).
9
IMPORTANTE
Al dorso encontrará información sobre cómo
este atenuador puede adaptarse a sus focos.
Garantie limitée
(Valide seulement aux États-Unis, au Canada, à Porto Rico et aux Caraïbes.)
Lutron réparera ou remplacera, à son choix, tout appareil jugé défectueux quant aux matériaux
ou la fabrication, pendant un an après la date d'achat. Pour le service de garantie, retournez
l'appareil au détaillant ou à Lutron par poste affranchie au 7200 Suter Rd., Coopersburg,
PA 18036-1299 U.S.A.
Cette garantie remplace toute autre garantie expresse et la garantie implicite de qualité
marchande est limitée à une durée d'un an suivant l'achat. Cette garantie ne couvre
pas les frais d'installation, de retrait ou de réinstallation, ni les dommages résultant
d'un mauvais usage, d'abus, d'un mauvais câblage ou d'une installation inadéquate.
Cette garantie ne couvre pas les dommages indirects ou consécutifs. LA RESPONSABILITÉ
DE LUTRON QUANT À TOUTE RÉCLAMATION POUR DOMMAGES DÉCOULANT DE OU LIÉS
À LA FABRICATION, LA VENTE, L'INSTALLATION, LA LIVRAISON OU L'USAGE DE L'APPAREIL
NE POURRA EN AUCUN CAS EXCÉDER SON PRIX D'ACHAT.
Cette garantie vous accorde des droits légaux précis et il se peut que vous ayez aussi d'autres
droits, selon les États ou Provinces. Certains États ne permettent pas de limiter ou d'exclure
les dommages indirects ou consécutifs ni de limite quant à la durée de la garantie implicite,
alors les limites ci-dessus peuvent ne pas s'appliquer dans votre cas.
son marcas comerciales de Lutron
de Lutron Electronics Co., Inc. NEC est une marque déposée de National Fire Protection
Association, Quincy, Massachussets.
© 2011 Lutron Electronics Co., Inc.
Ayuda +1.888.235.2910
México
U.S.A., Canada and the Caribbean
1.800.523.9466
México
+1.888.235.2910
Others | Otros | D'autres
+1.610.282.3800
Fax | Télécopieur
+1.610.282.6311
CFL/AFC
LED/DEL
600 W à
150 W ampoule
OU
incandescence
fluorescente compacte
ou halogène
(AFC) ou à DEL
AYCL-153P (Ariadni) | TGCL-153P (Toggler)
Veuillez vous référer à l'illustration
correspondante à gauche
Danger d'électrocution. Peut causer le décès
AVERTISSEMENT
de la personne ou de graves lésions. Couper
le courant au disjoncteur (ou retirer le
fusible) avant de proceder à l'installation.
Retirez les vis de montage de la plaque murale et de l'interrupteur. Laissez tous
les ls raccordés et retirez délicatement l'interrupteur du boîtier mural.
Identi ez le type d'interrupteur. Un interrupteur unipolaire sera doté de ls
isolés reliés à deux vis de même couleur, plus une vis de m.a.l.t. verte. (Se
référer aux diagrammes un interrupteur unipolaire
A
et
A
)
1
2
Les interrupteurs à 3 voies seront dotés de ls isolés reliés à trois vis et
plus une vis reliée à la terre verte. Un de ces ls sera relié à une vis de
couleur différente (non verte) ou étiquetée COMMUN. Étiquetez ce l a n
de pouvoir l'identi er lors du recâblage. (Se référer aux diagrammes 3
voies
B
et
B
)
1
2
Déconnectez les ls de l'interrupteur. Il se peut que votre commutateur
mural ait deux ls raccordés à la même vis. Enrubannez ces deux ls
ensemble avant de les déconnecter.
Pour les installations avec plus d'un contrôleur dans un boîtier mural. Voir
le paragraphe intitulé Jumelage multiple et utilisation simultanée
de différents types d'ampoules sur le gradateur (au verso).
Préparer les Fils.
Bornes à pression : Insérez les fils complètement. Note : Les bornes à
pression sont pour utilisation avec des fils en cuivre massif 1,5 mm²
(14 AWG) seulement. Pour les édifices à fi ls d'aluminium, consultez un
électricien. NE PAS utiliser du fil toronné ou torsadé. Ou base à bornes
vissées : Serrez fermement les fils sous les vis. Les bornes à vis ne doivent
être utilisées qu'avec des fils de cuivre massif. Pour fils d'aluminium,
consultez un électricien. Ne PAS utiliser de fils multibrins torsadés.
6A : Remplacement d'un interrupteur unipolaire
L'interrupteur sera remplacé par un gradateur.
a. Connectez le fil de mise à la terre vert du gradateur au fil de
Voir
terre en cuivre nu ou vert du boîtier mural.
A
(Voir la remarque 4 des Remarques importantes).
2
b. Raccorder un des fils libres qui ont été précédemment enlevés de
l'interrupteur à la vis de couleur différente (ou le trou du fil noir) sur
le gradateur.
c. Raccorder le fil restant précédemment enlevé du commutateur à la vis (ou
le trou du fil noir) du côté opposé de la vis de couleur différente.
6B : Remplacement d'un interrupteur à 3 voies
Si un gradateur est installé dans un système commandé à partir de
plusieurs emplacements, l'intensité d'éclairage pourra être contrôlée à
partir d'un (1) emplacement et les lumières pourront être allumées et
éteintes à partir de tous les autres emplacements.
Voir
a. Raccorder le fil de cuivre nu ou le fil de mise à la terre vert à la vis
verte du gradateur (se référer à la remarque importante 4).
B
b. Raccorder le fil étiqueté précédemment enlevé de l'interrupteur à la
2
vis de couleur différente (COMMUN) (ou dans le trou de fil noir) sur
le gradateur. Si deux fils sont entourés conjointement avec du ruban
adhésif, raccorder un des fils à la vis et insérer l'autre dans le trou
de fil noir près de la vis.
c. Raccorder un des fils libres qui ont été précédemment enlevés de
l'interrupteur à l'une ou l'autre des vis restantes (ou aux trous de fil noir) sur
le gradateur.
d. Raccorder le dernier fil précédemment enlevé de l'interrupteur à la vis
restante (ou au trou de fil noir) sur le gradateur.
Positionnez soigneusement les ls dans le boîtier mural et montez
le gradateur, mais sans installer la plaque de façade pour le moment.
Rétablissez le courant au disjoncteur (ou remettez le fusible et refermez le
sectionneur).
Pour d'information sur la façon de régler ce
IMPORTANT
gradateur pour vos ampoules particulières,
voir au verso.
sont des marques de commerce